Recently active
Similar to how most other CREO files have iteration #'s, add the iteration number ( .1, .2, .3 ...) to the end of the file name of creo_parametric_customization.uicreo_parametric_customization.ui.1creo_parametric_customization.ui.2creo_parametric_customization.ui.3This allows recovery of a setting that may have been changed unintentionally. The previous customization file "config.win.x" used the iteration number.
I would like to propose an idea to add a command that allows you to put some locations in a group so that they can move together simultaneously. I often find myself having to use some tricks to make the network between them bribes so that the cables pass through the network by autorouting, but then, if I want to move those locations I need to move them one by one. Adding the locations in a group It would be easier.
Now in drawing module in Creo Parametric you see all of lines in the same thickness (but in different colours for different type of lines). In prepared drawing in pdf you see real tickness (conerted by pen table). It will be cool to see real tickness of all of lines in process of drawing in Creo.Here you see that solid line and hatch line in the same thickness (first picture) , but it will be cool to see it in real different thickness (second picture).
currently, removing Component Names (from ECAD_REF_DES column) by using the NAMES menu in MODEL PROPERTIES, does not remove the REF DES LABEL note. Since the note is just an annotation method to show the name, it should not be there when the names are removed. Users are forgetting to remove the note after removing the names are are confused why it still shows when they are showing the reference designators.This is in reference to case 12958332.
Hi.I would like to suggest new function "Split Surface by Curve".This function exists in Creo Simulate - "Surface Region".I need same functionality in Creo Parametric.Note:There is also automatic splitting in Moldesign.ThanksRegardsMartin Stary
Referring to PTC Case C12994725, my company has legacy parts which have been in use for many years which directly conflict with IFX part names. The parts are used throughout our products making renaming of the legacy parts unworkable as I would have to open hundreds or possibly thousands of assemblies during the rename. These legacy parts are stored on a network drive for common usage. When I initiated use of Creo 3 with IFX the assemblies failed due to constraint mismatch with the new IFX parts. I found that the IFX parts were loaded before any search.pro from my config.sup or config.pro. I tried turn off the IFX functionality using the config.pro option. No effect.My suggestions as to possible solutions are: allow a search.pro called from the config.sup to load before the IFX search.pro, rename the IFX parts to include the prefix AFX_ or IFX_ to differentiate them from any customer legacy parts, or turn off the IFX search.pro when the IFX functionality is turned off.
Today, wirebonds cannot be imported via IDX as the file format does not support them. This request is to work with the IDX consortium to allow the exchange of wirebonds between electrical CAD tools and mechanical CAD tools. Our company designs a number of products that use wirebonds, and in the ECAD / MCAD exchange process, these circuit card features are not translated. Additionally, there is no alternate flow that will provide a way to get the wirebond structures into Creo Parametric, along with all of the other electrical components, for communication of changes through IDX.
Currently, ModelCheck will only find extruded holes that should be regular holes, if the user creates only one hole in the extrude. So the user has a choice..either:1 - Use a hole feature, which is a little more work, and our current company policy, or..2 - Use the loophole, (which makes his life even easier) and extrude all holes in one sketch!If there are more than one hole in one extrude sketch, CYL_CUT_SLOTS will not be flagged in ModelCheck. I believe this doesn't promote proper modeling behavior, rather it promotes the loophole, which is even worse. Please improve the checking process for this.Thank you.
When trying to Save an Assembly that has a WindChill Modification Conflict with a submodel, and then setting the Action to READ ONLY, the Assembly will not be saved initially. Saving the assembly again WILL work. This is critical as users think their work is being saved initially and then they end up losing everything if they close out of Creo without saving again. The small error message is not enough. There should be a use-case scenario within the software that saves the assembly even if a submodel is set to READ ONLY.PTC says that this is a change in behavior and thus, this improvement idea is created!
Add functionality to the piping module that allows for beads to either be created or shown on the end of pipe segments. Currently beads need to be created outside the piping module as a separate part & assembled or as a assembly feature. Both methods do not allow for full association to the pipe feature itself.
This may be a repeat request (but I didn't see one when I searched).There may also be another option than what I'm proposing here, so please be kind.This is a request to allow ModelCHECK to flag specific density values (like an itemized list of values) that are bad. Today, the DEF_DEFAULT setting looks for 1.00. That's fine in some cases, but not all. Imported vendor models will often have densities assigned that are not 1.00, a value based on the material, or even a value that's anywhere near a realistic value. This means ModelCHECK skips them.This request would effectively allow us to use an "OR" statement.Here's an example: IF density = 0 OR density = 1000 OR density = 1.2345 THEN issue an error. Something like that.I don't know if this would also require some sort of tolerance/accuracy, or would read the exact value including significant digits. 1.00 vs. .999. I realize that we'd could end up with a pretty long list, but the cap
Below functionality need to be done through toolkit:-- Set Start (under Routing tab of piping application)-- To Pnt / port (under Routing tab of piping application)-- Pipe Solid (under Fabrication tab of piping application)Thanks and RegardsKetan
Hi,Currently, we are not getting any report parameter for pipe segment length i.e. length between two bend in pipe.So our idea is to create repeat region report parameter for segment length.e.g. shown in below snapThanks,Prashant Pandarkar
Modelcheck help indicates that you can combine several start files into a single configuration. The example they gave was PRT_PARAMETER WIDGET STR EQ GREEN in one file and BLUE in another. After speaking with support, this will ONLY work if the "first three items after start tag (Mode) in the start item are same (WIDGET STR EQ)". However, if the two start files include PRT_DATUM PLANE 'name' 'number' and the name changes with the same number then it will not work. Modelcheck should be able to use the last start file and understand that the feature name will be different for the feature number and not flag it as an error - no matter what is listed, since it will be in violation of at least 1 start file.
It would be great if there was a way to accomodate using 2 different size clearance holes, as is necessary when using a shoulder bolt. You need a clearance hole on the top layer for the shoulder, a smaller clearance hole for the second surface (which the shoulder rests on), and then a nut on the bottom surface. To broaden the suggestion: It would be great if in the IFX references dialogue, there was an advanced option that allowed for non generic fasteners like shoulder bolts, anchor nuts, barrel nuts and others that require more than just a surface and axis reference (that aren't uniform around an axis).
Currently it is not possible to allow for drawings to have no format while using ModelCheck FORMAT_NAME option. Please add an option to allow no format as we create DXF drawings without drawing formats and need an ModelCheck option to allow a drawing to not have a format. This would be option the Creo Admins could decide to use or ignore. Another way to "solve" this today would be turning off the format display but this would require a change of a lot of legacy drawings. It would be much simpler to have to option of allowing no formats or not.
Добрый день there is no solution how to let users simply pass through MCH pop-up prompt asking to perform a drawing check. Users always have to type Y/N and confirm some option. It is annoying and wasting of time for most of them. According to our beloved PTC there is no option driving it (except Toolkit) and workaround given in this case is silly bcs calling macro or clicking dialog is almost the same. My suggestion is to add config option like "MCH_run_on_dwg_models" with 3 options: Yes - Always run on all drawing models/sheets (don't ask user = no dialog) No - Always run on current drawing model/sheet only (don't ask user = no dialog) Ask - Ask user (same as now = show dialog)
https://community.ptc.com/t5/Discussions/Material-and-covering-for-the-fasteners/m-p/479151#M141 One of the solution is to add SUBTABLES in dat files like in AFX. Need to possibility to select a material, covering and so on (a value to model parameter) from drop down menu. Without a need to duplicate dat files.
ModelCHECK should be enhanced to have a check to inform the user if a table is missing. Currently there is only a check to see if the values are correct in specific cells (DRW_TABLE_CELLS ), but not if the table exists.
A drawing dimensions that is set to "Tolerance Value Only" should be flagged by ModelCHECK as an overwrite dimension. Currently, we are getting a lot of fake values by engineers who are adding text to dimensions that are set to display the tolerance only.
When modifying the original value of the fillet in a sketch there are 2 different conditions that are causing constraint related failures.1) 1) When there are 2 intersecting lines that are not in the horizontal or vertical position.2) 2) When there is an intersection between entities that are not lines. (Arcs or Splines)With the shown example I have locked the dimensions that I need to keep the sketch stable.With case 1 even though the intersection is dimensionally locked when a fillet is applied it replaces these constraints.Creo even recognizes the error it creates as shown below.When you modify the fillet to the needed size it will invariably move the position as shown below.With case 2 instead of having 2 lines I have replaced one of the lines with an arc. (The same type of results apply with using a spline), once again when I place a fillet it removes the original locked constraints. Once again in the message tree y
The Proj. Ref. Point in Annotation only supports normal Lines. It might be possible to select Arcs.Der Projiz. Bezugspunkt im Annotation sollte auch Bögen unterstützen und nicht nur gerade Linien.
Sehr geehrte Damen und Herren,wenn ich mit Creo 2.0 eine Zeichnung öffne, dann ist immerdie Registerkarte "Layout" aktiv.Nun habe ich mir eine neue Registerkarte erstellt mit meinem Namen.Man sollte die Multifunktionsleiste so umdefinieren können,dass unmittelbar nach dem Öffnen einer Zeichnung die selbst erstellte Registerkarteaktiv ist.Im Moment ist nach dem Öffnen einer Zeichnung nach wie vor die Registerkarte "Layout" aktiv.Dies kann man zur Zeit nicht umsellen.
In Annotation, it would be great if one could generate a stagger dimension without having to stagger a dimension manually that are grouped closely or slightly overlap each other,
Below are a few suggestions to help constrain the model better by removing unecessary 0 dimensions:Config option that defaults a constrain type for Mate/Align to coincidentSheetmetal Flat/Flange Feature: be able to constrain the ANGLE by Perpendicular, Parallel...Sheetmetal Flat Feature: be able to constrain the edge offset without going into the sketch to coincident
Already have an account? Login
No account yet? Create an account
Enter your E-mail address. We'll send you an e-mail with instructions to reset your password.