Recently active
I'd like to share newly created, updated or helpful WGM (Pro/ENGINEER Wildfire / Creo Parametric / Windchill Workgroup Manager) related Articles authored, updated or come across in my day to day activities. I'll be posting new lists of issues you may come across every few months or so:How-to's, Configuration and Feature Information:CS170683 - How to import files into a Windchill Workspace using Windchill Workgroup Manager VFS bulk importCS165246 - Information about the Private Checkout feature in Windchill 10.2CS46007 - Pro/ENGINEER Wildfire, Creo Elements/Pro, Creo Parametric and Windchill Workgroup Manager Windchill Cache Upgrade Compatibility, Downgrade Compatibility, Version Access Compatibility and Best PracticesCS131176 - Guidelines for Workspace and Workspace cache usage when using Pro/ENGINEER, Creo Elements/Pro, Creo Parametric and the Workgroup Manager with Windchill PDMLinkCS37763 - Recommended values for Cache Size or Cache Limit in Pro/ENGINEER Wildfire, Creo Element
I'd like to share newly created, updated or helpful WGM (Pro/ENGINEER Wildfire / Creo Parametric / Windchill Workgroup Manager) related Articles that I author or come across in my day to day activities. I'll be posting new lists of issues you may come across every month or so:How-to's and ConfigurationCustomer Presentation on Optimizing Client-Server InteractionCS56377 - How to automate Creo end user testing in Windchill PDMLink Feature Information:CS151515 - Internet Explorer versions 10/11 and Windows Operating Systems support with Windchill PDMLink 10.1 and 10.2CS55934 - Platform support information for Pro/ENGINEER, Creo Elements/Pro and Creo Parametric Performance Tuning:Performance Impact of Debug Client Logging, In vs. Out of Process Browser and HDD vs. SSDCS158788 - Opening NX assemblies in linked sessions with the Windchill Workgroup Manager takes longer than a standalone NX session Errors/Issues:CS159196 - Checkin fails in Windchill PDMLink 10.2 with error "A datastore
I'd like to share newly created, updated or helpful WGM (Pro/ENGINEER Wildfire / Creo Parametric / Windchill Workgroup Manager) related Articles that I author or come across in my day to day activities. I'll be posting new lists of issues you may come across every month or so:Feature Information:PTC Creo Future Platform Support Summary Errors/Issues:CS159857 - Related Generics are not collected in Windchil 10.2 M010 when checking out an assembly instance and the family table is component drivenCS157088 - Check In fails in Windchill 10.2 M010 with error "Cannot insert duplicate key row in object 'windchill.WTPartUsageLink' with unique index 'WTPartUsageLink$UNIQUE50'. The duplicate key value is ()" after reordering the Item Number in the CAD toolCS159882 - Remove from Workspace for some datasets performs poorly in Windchill 10.2 M010 vs. 9.1 M070CS157893 - Retrieving an assembly from workspace, having components the user has read only permissions on only, will cause Creo Par
I'd like to share newly created, updated or helpful WGM (Pro/ENGINEER Wildfire / Creo Parametric / Windchill Workgroup Manager) related Articls that I author or come across in my day to day activies. I'll be posting new lists of issues you may come across every month or so:Feature Information:Bulletin & CS133804 - Windchill Workgroup Manager 10.1 M040 Functional Patch and Support for Additional CAD Versions (6-Jan-2014) Errors/Issues: CS141939 - MethodServer issues Low Memory warning due to collection service in Windchill PDMLink 10.1Bulletin & CS133804 - Windchill Workgroup Manager 10.1 M040 Functional Patch and Support for Additional CAD Versions (6-Jan-2014)CS156420 - Collect objects window hangs in Workgroup Manager 10.1 when users try to checkin Solidworks objectsCS155061 - Creo Parametric may go offline reporting "The server is currently unavailable. Do you want to switch to offline mode?" and may exit prematurelyCS152747 - SolidWorks and Windchill Workgroup Manager
I'd like to share newly created, updated or helpful WGM (Pro/ENGINEER Wildfire / Creo Parametric / Windchill Workgroup Manager) related Articles that I author or come across in my date to day activities. I'll be posting new lists of issues you may come across every month or so:Feature Information:CS133804 - Support for additional CAD Versions in 10.1 M040 Windchill Workgroup Manager Temp PatchErrors/Issues:CS150434 / SPR 2201623 - Assembly will not save in Windchill PDMLink 10.1 with Read-Only components in Creo Parametric 2.0 M080CS150757 / SPR 2201930 - When a local cache created with Creo Parametric 2.0 M070 or older is opened by M080, the Local Workspace status is wrongCS38519 - Attempting to "Undo Checkout" of an Object shows error "The object was improperly initialized (i.e., it was null)" in Windchill PDMLink 9.1CS155061 - Creo Parametric may go offline reporting "The server is currently unavailable. Do you want to switch to offline mode?" and may exit prematurelyBulletin
I'd like to share newly created, updated or helpful WGM (Pro/ENGINEER Wildfire / Creo Parametric / Windchill Workgroup Manager) related Articles that I author or come across in my date to day activities. I'll be posting new lists of issues you may come across every month or so:How-to's and Configuration:CS24192 - [TS KP] Pro/ENGINEER Wildfire Interaction with PDMLink - Recommended Initial Performance Server SettingsCS150977 - Best Practice To Reduce Workspace Refresh TimeCS145351 - The "Enhancement Details: PTC Windchill 10.2 F000" guide mentions support for Universal Upload, what datecodes will support this new functionality? Performance Tuning:CS24192 - [TS KP] Pro/ENGINEER Wildfire Interaction with PDMLink - Recommended Initial Performance Server SettingsCS150977 - Best Practice To Reduce Workspace Refresh TimeErrors/Issues:CS148498 - Save As performs poorly for assemblies with circular dependencies and components with multi-occurrencesCS138991 / SPR 2191166 - Windchill Workgr
PTC has recently made several Windchill 10.1 M040 temp patches available that address a number of issues:Add support for the following CAD versions:SolidWorks 2014CATIA V5-6R2014NX 6.0 (formerly Unigraphics/UG-NX)Resolves 44 functional issues (premature exits, unresponsive clients, performance, product structure issues, etc.).Take a look at the following for additional detail:CS160577 (https://www.ptc.com/appserver/cs/view/solution.jsp?n=CS160577) - Windchill Workgroup Manager 10.1 M040 Functional Patch and Support for Additional CAD Versions (12-June-2014):
PTC has recently made several Windchill 10.1 M040 temp patches publicly available that address a number of issues:Resolves 12 functional issues (premature exits, issues with related product structure, performance, etc.)Resolves 2 functional issues with communication between the Windchill Workgroup Manager and the Windchill ServerAdds support the following CAD Versions:AutoCAD 2014Autodesk Inventor 2014CATIA V5-6R2013Creo Illustrate 3.0Take a look at the following for additional detail:CS133804 - Windchill Workgroup Manager 10.1 M040 Functional Patch and Support for Additional CAD Versions (6-Jan-2014)CS155369 - Windchill Workgroup Manager 10.1 M040 Functional Patch (17-Dec-2013)Note: The 10.1-M040_WWGM_PS_8 patch has been superceeded by the 10.1-M040_WWGM_PS_15 cummulative patch. See CS160577 or this blog post for additional detail.
PTC has recently made a pair of Windchill 10.1 M040 temp patches publicly available that address the following issues:Poor performance using Creo Parametric or Windchill Workgroup Manager when the user has access to hundreds or more Products, Libraries or ProjectsFunctional issues with the Windchill Workgroup Manager communicating with WindchillTake a look at CS141139 - Windchill Workgroup Manager Performance and Functional PatchNote: The 10.1-M040_WWGM_PS_2 patch has been superceeded by the 10.1-M040_WWGM_PS_8 and later 10.1-M040_WWGM_PS_## cummulative patches. See CS133804 or this blog post for additional detail.
During recent troubleshooting of a performance issue and discussion with R&D, I tested a number of environments to get a better idea of the performance impact of debug logging, in vs. out of process browser and HDD vs. SSD disk on Workgroup Manager transactions (add to workspace, content download) and retrieval.I started out with only the top level assembly (~400 component) in the workspace and performed a retrieval on the fly using Creo Elements/Pro 5.0, Creo 2.0, Windchill PDMLink 10.1 M040 with following differences in environment:No debug client logging + in process browser + SSDNo debug client logging + out of process browser + SSDNo debug client logging + out of process browser + HDDDebug client logging (CS140107) + in process browser + HDDDebug client logging (CS140107) + out of process browser + HDDResults are as follows:Retrieval + Add to Workspace 400 component assy simp rep LAN Windchill 10.1 M040 Start with Assembly in the WorkspacePerfDebug LoggingCache &TEMP on H
I recently had the opportunity to present to a group of PTC customers regarding client-server interaction optimization. The presentation discusses a number of topics:Client ConfigurationConfiguring and Validating a ClientNetwork ConsiderationsServer & Database ConfigurationBenchmarkingRunning a Benchmark TestResourcesSee the presentation below.
Welcome to my blog! I'm Craig Pater and work in PTC Technical Support in the Interface Solutions, Visualization and most recently the Technical Leaders groups. I've supported and continue to support a number of PTC products and functionality over the years:Pro/PDMPro/INTRALINKPro/INTRALINK ToolkitPro/ENGINEER or Creo interaction/integration with WindchillProductView or Creo View client & adaptersDivision ProductviewWindchill Visualization ServicesPLM ConnectorWindchill Workgroup ManagerThinking back, I started working with Pro/E 20, Pro/PDM 3.5, Pro/INTRALINK 1.2 and Windchill in the early 6.2 releases (does anyone remember the Java based Workgroup Manager for Pro/E 2001)? Things have come a long way since then with Wildfire, Creo and Windchill. In the last several years I've concentrated on Creo/Windchill Workgroup Manager interaction, functionality, performance and stability when working with Windchill. I also create and deliver training to other TSEs as w
Are you experiencing poor server performance managing Creo or Windchill Workgroup Manager (CAD) data in Windchill?Do you wonder what you should do to setup or tune a Windchill server for interaction with clients working with CAD data?Look no further! Technical Support has an Article that walk typical setup and tuning that one should perform when managing CAD (EPM Documents) in Windchill:CS24192 "[TS KP] Pro/ENGINEER Wildfire or Creo Interaction with PDMLink - Recommended Initial Performance Server Settings"Setting some key server settings, performing some database tuning and then benchmarking the server will ensure it performs well and users have the best possible interaction with the server.
I'd like to share newly created, updated or helpful WGM (Pro/ENGINEER Wildfire / Creo Parametric / Windchill Workgroup Manager) related Articles that I author or come across in my day to day activities. I'll be posting new lists of issues you may come across every month or so:How-to's and Configuration:CS23960 - [TS KP] Pro/ENGINEER Wildfire and Creo Interaction with PDMLink - Recommended Initial Performance Client Settings is now customer viewableCS126670 - How to use the PTC System Monitor (PSM) in Workgroup Manager Transaction Performance DiagnosisCS20956 - Cause and Resolution of Incomplete, Ghost objects or Placeholder Documents when using Creo Elements Pro with Windchill PDMLinkCS28858 - How to remove legacy, invalid, default references in drawings or layouts or models in a linked session with WindchillCS130553 - Step by Step Process to use Windchill Client Inspector to inspect relevant Pro/ENGINEER, Creo Elements/Pro, Creo Parametric or Windchill Workgroup Manager Windchil
Are you experiencing poor performance with Creo or Windchill Workgroup Manager (WWGM) clients interacting with Windchill?Do you wonder what you should do to setup or tune a client for interaction with Windchill?Look no further! Technical Support has a pair of Articles that walk through 6 steps one will perform when tuning a client for performance:CS23960 "[TS KP] Pro/ENGINEER Wildfire and Creo Interaction with PDMLink - Recommended Initial Performance Client Settings"CS140968 "[TS KP] Windchill Workgroup Manager Interaction with PDMLink - Recommended Initial Performance Client Settings"Installing an updated IE browser, setting some Windows Registry values and a couple config/wgmclient.ini/environment settings can in many cases can significantly improve perfomance.