31 characters are not enough for design. This limit sometimes is driving customer crazy. For CATIA the limit of file name is 81 characters.

87 replies

Jan 16, 2017 6:25 PM UTC

Done - great suggestion Christopher

Feb 12, 2017 10:30 PM UTC

It is really true!!! 31 digits is not enough. I had complaint this many many years ago but somehow PTC can't change this, funny enough!!. And they do not seem to know how to do it (??)

Feb 13, 2017 2:45 AM UTC

I don't think it's easy to make this change, also like Creo is not a multi-tasks software, it's only a single- task program.

Maybe because it's transplanting from unix

Mar 13, 2017 12:02 PM UTC

A 32 character limit is not sufficient for designs. In today's conditions, most CAD programs allow more than 32 characters to be used. I think Pro / ENGINEER should be able to use more characters as soon as possible. Especially the EMN and EMP files we use during ECAD / MCAD studies are very troublesome.

Mar 23, 2017 4:54 PM UTC

To handover data in Creo 4.0 from CATIA, NX via UGM makes not really fun if the original file name has to be shortened. ame problem handling idf or idx files from ecad systems if the footprint name is equal in the 1st 40 chars. It is a must which is long overdue.

Mar 24, 2017 8:53 AM UTC

If you do so, dont forget about simulation analysis. Nothing more annoying than an analysis failing because of a too long analysis name and you start to search around to get the solution without having that in mind.

Mar 24, 2017 9:33 AM UTC

Good idea, and please, add special characters like point, commas and blank spaces!!!

Apr 18, 2017 11:08 AM UTC

I had opened PTC E-support case and I was promised that the linger file names will be allowed in Creo 4.0

But it is really disappointing to see that the issue is still not addressed in Creo 4.0

Can anyone from PTC explain why it is such a big deal to allow more than 32 characters part file name.

As a product designer it is highly annoying to name a file with 32 characters limit and the limit to add comma, dot adds up to it.

This feature is desperately needed....

Apr 19, 2017 4:55 AM UTC

I can explain, sure.  There are a very large number of places in the code where a buffer is allocated to hold a model name, and the buffer is 32 (31+trailing NULL) wide characters.  If model names were longer, writing to this buffer would overflow the end, and damage some bit of memory just beyond.  Similar cases exist with storing A.PRT, or A_INST<A>.PRT, or various other forms.  Or perhaps some identifier 'A (part) feature 123 parameter FOO', where how the identifier is used now works okay because 'A' is at most 31, but would break if the part name had 200 chars.  Most individual types of the issue can be addressed without too much difficulty, but not all of them.

All of this is potentially addressable, it's just that the work involved touches on the entire code base, and figuring out what all would need to be changed in advance is tricky.  And we need to be reasonably sure we got everything right, as the cost of missing something is fairly high.

Apr 19, 2017 9:23 AM UTC

Ya Matthew ,

Thanks for explaining this elaborately.

I understood that there is some kind of technical limitation to this & it is difficult but indeed possible for you to address this.

As a user , not only me, but most of us are facing high degree of inconvenience because of this.

I am sure you will priorities user's convenience over your limitations.


Some of the CAD software are already allowing more than 32 characters.

I feel this is the time for PTC to do this, I would be highly disappointed, if still the issue is not resolved now.

My file system is messed up because of this limitation.

Please come up with a date, when you are allowing longer file names.