Windchillers,Can anyone provide a rough estimate of the duration required for Windchill Oracle to SQL migration ?The Windchill version is 10.2 & Oracle version is 11.2.0.3. The DB size is around 45 GB. Please enlist anything that would be a key factor for planning,What could be the most frequent issues encountered ? Is there any better approach that you might have discovered ? -Thank you,Vaibhav.
How to configure Windchill to enable integration with an SSO provider?Need help with the configurations that are required on Windchill to enable SSO (with Siteminder/Sentry etc..), and configurations that are needed on SSO as well.If anybody is aware of any documentation or help pages that will help, please let me know
For a product that has multiple external collaborating entities (suppliers, design partners) , there is only a single project related to the product and multiple folders are created for managing suppliers with in the same project. say folder1 for supplier1. folder2 for supplier2, folder3 for designPartner3 etc... And collaborating partner users have access only to their folders. And there is often a business need to share the same design data with multiple partners. Which means that we need to be able to share the same data to multiple folders in the same project, which in Windchill 10.1 OOTB seems to be restricted for now. Is anyone aware of any solution for this? Or is there a better strategy for handling multiple partners than using multiple folders?
Hello,we are upgrading to Windchill 11 M010 from 10.2 M030.But while Windchill 11 Installation, it is getting failed Failed with Error "Password validation failed. The password does not meet Windows policy requirements because it is not complex enough" although we are providing complex password. This error comes while new DB schema and user creation in Sql Server 2012.When check PC knowledgebase, found that this issue is know and it is a PSI bug and SPR is filed for this issue. workaround is to disable the domain password policy but unfortunately it is not possible in our environment as domain controller person said no for disabling this policy.PTC is saying they do not know when it will be fixed. But we had shared server upgrade rollout plan to all stake holders and now we are delayed by two weeks.Is there any follow members who also found this issue while upgrading to Windchill 11 M010 with SQL or Oracle server?Also is there any workaround or solution apart from disabling the passwor
So when I create the zip, I don't want the extra files. I am hoping that someone has more information on how to eliminate these without having to physically remove them.
Anyone out there has had success implementing the now PTC supported form based authentication (CS110583) with Windchill and the wcadmin account ?Windchill command line tools that need authentication such as BulkIndexer, WindchillLoader, WinDU, etc are not working and PTC is does not havesupport documentation for it.
We are working on a Windchill workflow project and found that when a task is submitted for review, the resulting objects associated to the task remain In Process and available for further edits. This behavior is different from Promotion Requests where the associated objects are also placed Under Review.We prefer to use Tasks because of the traceability they provide and allowing association of unrelated objects. However, we would like functionaltiy similar to Promotion Requests once they are submitted. Can anyone provide suggestions how this might be accomplished?Regards,Jim
We are currently looking to enhance out processes in the MCAD/ECAD arena. Currently, we have ECAD designs (CCA and PCBs) managed as WTDocuments. It has worked well for a long time. I am looking at the WGM for Cadence but I have a question about detailing. Where do most people detail their CCA and PCB drawings? Has anyone taken the step to do all of their detailing in Creo?This is what I am looking at. Traditional design takes place in Allegro. Where we would normally have exported that information to AutoCAD for detailing, it would be done in Creo. The WTDocument held all the content before (Allegro data, AutoCAD drawing, PDF and ODB++) via primary content and attachments. In the new model, the IDX file creates the 3D model which is shown on the drawing along with and DXF exports from Allegro for fine detailing. The Allegro design and ODB++ data can be archived as attachments to the Cad Document. I am not an EE so please excuse my over-simplification
Hi,i have used,Process p = Runtime.getRuntime().exec("cmd /c \"start sqlplus system/manager && CREATE OR REPLACE DIRECTORY export_dir AS 'E:\';\"");application connected to oracle database successfully using command sqlplus system/manager. but second command CREATE OR REPLACE DIRECTORY export_dir AS 'E:\';does not work as shown in Image attached. Plz let me know how to execute multiple commands on cmd.exe one by one . Please check syntax to run multiple commands in Process p = Runtime.getRuntime().exec("cmd /c \"start sqlplus system/manager && CREATE OR REPLACE DIRECTORY export_dir AS 'E:\';\"");ThanksManoj
We are using some publishing rules to create DXF and STP files for CAD publishing. When we apply additional rules to only create the DXF/STP files only at certain states (Released and Pre-Production Release), it does not work as expected. If I manually publish the CAD while at the target state, the DXF/STP files get created. If I Set State or Promote the CAD to the target states, the viewables are derived from the non released state and the DXF/STP files do not get created. Is there a method to enforce the publishing rules upon Set State/Promote/ECN to the n target state?--Kirk WempleNewell Brands
We are running Windchill 10.0 m040 and have run into an issue with incompatible Java installs on some users machines who are running another program that required them to have Java 8 update 66 installed.In trying to get to a common Java environment between the 2 programs, what version and update is the highest that will work with Windchill 10.m040?We are in the early planning stages of upgrading to Windchill 11.0 m010, but like my manager just said, it is a low priority and the time frame slips as other things impact what I have time to work on. I do plan on upgrading by the end of March 2017, but even that can slip again.
I have legacy data from Pro IntraLink that I want to import into Windchil PDM Essentials.However, most of the legacy data is not at Rev A.1.So how do I import the legacy data and set at a revision higher than Rev A.1...say Rev B.2 for example.
I created a Product in my production server that separated from the rest of the other products. I have set up a Team and given them access restrictions so that they don't mess up or go into the other product folders. The problem is, I am trying to grant one user the ability to create workflows and templates but he cannot see them. I tried following the procedure in CD33694 "How to grant permission to user to be a workflow administrator in Windchill PDMLink" (https://support.ptc.com/appserver/cs/view/solution.jsp?n=CS33694&art_lang=en&posno=1&q=how%20to%20grant%20a%20user%20wor…)but there is no "Prinicipal Administrator" present under site/utilities view when I am logged in as Site and Org Admin.There is a foot note saying, "It will be necessary for the user to have access to the Utilities menu such that they can access the workflow templates. At a minimum, the user would need to be in a context management role (product / library manager)" can someone point
I am getting the error message "Invalid server location. Please change the Location field and try again" in Server Manager when trying to connect Creo Parametric to Windchill. Solutions?
I work in Sourcing and quite often need to create RFQ - Request for Quote with suppliers that need complete product specifications to go with it.Given a multi-level product structure, is there a feature in Windchill that allows me to download all related objects (drawings, material specs, etc.) at once?Currently, I am going item by item in the product structure and downloading one document at a time.Your help is much appreciated, thank you.
Hi."New branch table" appears with preselected second element in combobox.Is it possible to customize? First element of combobox should be selected.Thanks.
I have set up the AfterEDRloader according to CS216668.Everything is working fine. My pdf is shown as an attachment.But I want to add the lifecycle state in the filename. This should not be that hard to do?I guess I just need to modify the AfterEDRloader.java file but I dont know how exactly.Anyone with experience of the AfterEDRloader method?
Users often find that, uninstallation & re-installation of Windchill Workgroup Manager is a tedious task with lot of interaction required when PTC posts newer WWGM-CPS.PTC has taken into consideration this problem & from Windchill 11.0 M010 onwards, we have enhanced to update WWGM on client system without un-installation of WWGM Client in many of the user scenario's !!!Below illustration/examples helps you to understand this enhancement.The following update scenarios are supported:Updating Windchill Workgroup Manager from 11.0 M010 to 11.0 M010 CPSUpdating Windchill Workgroup Manager from 11.0 M010 to 11.0 M020Updating Windchill Workgroup Manager from old 11.0 M010 CPS to later 11.0 M010 CPSYou can add new CAD WGM modules to an existing Windchill Workgroup ManagerExample1: When SolidWorks WGM is installed, adding NX WGMExample2: When SolidWorks 2015 WGM is installed, adding SolidWorks 2016 WGMKnown limitations:You cannot remove the installed CAD WGM module when updating Workgro
I am trying to add some users with an ACL for their group to have read-only access to drawings in any state.As an emergency fix, we put one user in the design group, which has read and write access to drawings and models. This is too much for this group of people.They are in their own functional group at the Org level as we use their group for sign-off on Change Requests. They want to see the drawings of the items that they are approving, not just the CR text.I tried assigning them to a read-only group and that did not resolve the issue, but there may be something else with that group.I tried adding a new ACL for in-work EPMdocumnets, but that is the wrong document type and it did not work.Looking in Type Manager, I cannot find an icon that matches the drawing icon to get the proper type name for a drawing. Does anyone have a cross-reference list of the Windchill type name to a common engineering name? Windchill 10.0 m040
Hi, have a good day.I'm doing some practices with windchill and trying to understand how it works. Now I have a doubt.What is the difference between these two prefixes in objects IDVR:wt.part.WTPart & OR:wt.part.WTPartThank You for your time.
All,Has any one successfully removed options from the Conflicts window when you modify an object in Creo Parametric that you do not have Checked Out?We set the Creo config option to default "Continue", but we are looking to remove the "Revise and Check out now" option. Users are inadvertently creating new revisions on top of the one that they are supposed to be modifying. Now instead of working on rev B, they are working on rev C without even knowing.Thank you in advance
Hello,Can anyone guide me with the steps to include Windchill attributes (IBAs) to the results being displayed in View Document app search results?I had created the the attribute in the Field Definitions in PTC.Resource.PLM.PartDataShapeAlso included the same in Example1DocumentAccessAppDataShape which is being used by the View Document appBut when i try to Configure Widget in DocumentAccessAppMashup, i don't see this Windchill attribute coming inCan someone help me on this?Thanks in Advance!!Amarkarthi
Hello AllIn Windchill 10.1, i am trying to open a part / assembly in Creo view.When the creo view tab opens, its shows an error "This visualization is marked out of date"And when i click continue, nothing happens, only blank screen.Please provide me solution for this problemThank youRegardsSumeet
The report that was create is able to show all the open task for a Change Notice except the review task.Used tableswt.workflow.engine.WfActivitywt.workflow.engine.WfActivitywt.workflow.engine.WfActivityWork Itemwt.workflow.work.WorkItemWork ItemUserwt.org.WTUserUserContextwt.inf.container.WTContainerContextChange Notice (wt.change2.WTChangeOrder2)wt.change2.WTChangeOrder2Change Notice (wt.change2.WTChangeOrder2)Used JoinsWork ItemSourcewt.workflow.engine.WfActivityWork ItemOwnership.OwnerUserwt.workflow.engine.WfActivityContextContextWork ItemPrimary Business ObjectChange Notice (wt.change2.WTChangeOrder2)Used criteriaWork.Item.Completed By Is null.When running the report all the open task are displayed except the review task..Does somebody has any idea what is special to the review task?
What is the extension of the file to be used and what are the steps to accomplish the import of a project file from one WQS license to another?