I am running Windchill 10.1 M040 and when I create a Purge Job, the window flashes with the "Archive Purged Objects" checkbox checked, then goes away? I do not want to archive these purged files but I can "uncheck" the Archive Purged Objects checkbox?
Hello,In order to Check-In only the eligible items, could we imagine to have this information in the Workspace.It allows designer :- to know which object are eligible for Check-In.- to sort object with this information in the workspace.- avoid Check-In action if business rules are not OK.Best Regards
I get confused between Modified by and authorization table in History tab
No puedeo mover un objeto de una tabla de familia porque "está extraído o se encuetra en una carpeta personal"el genérico. He verificado que ninguna iteración del genérico está extraído pero no tengo claro el concepto de carpetapersonal y cómo puedo acceder a las mismas.
Hi!I have trouble (Java heap space) when I try to create visualization of the large documents through the Adobe LiveCycle. How can I solve this problem?Windchill 10.1.
Hi folks,I am working on a workflow for a Variance and I need to find a way to send a task based on a date (or days from)?The author enters in an end-date for the Variance and then in the workflow I need a user to complete a task to close or extend the variance. I would like to send them that task the day before the end-date.Any ideas?I looked at using Ad Hoc but the Duration is not what I think it is. The task is sent at once.Action Items, same thing - the Action is sent at once even with a future Start date.
An issue in our Windchill 10.2 installation:Renaming a view in the View Administration, lets the Structure button in the context menu disappear.Any idea why this happens?regards, Michael
workgroup manager exits when registering authoring application.
Hi,I trying to clone my production server for that i did the followed steps,Copy the Windchill installation and third party product at the same directory structure from the source machine to the target machine (windchill and Apache directory) Install oracle on the new machine Run the PSI on the target machine and install java , WindchillDS and OCU Import the Production database dump on the New machine’s DBImport the LDAP to the Windchill DS on the New machineIf database is installed on the Production machine then no need to make any changes in db.properties file, else update “wt.pom.jdbc.host=<target host name>” in db.properties file of the target machine.After completed the above steps i tried to start the windchill, but its not started. Herewith i attached the MS log file. whether i followed the correct steps or anyone please suggest me the correct steps for that.Waiting for your valuable reply!!!!!
I wanted to cross check some class/java files between different environments?I don't have login credentials of those machines to do the same.Is there any way around for this?
OK, PTC sent me a link to
I am wondering what everyone is doing for associating WTParts to WTDocuments...For example, I am specifically interested in the following use case:We have a set of WTDocuments that are engineering specifications. They cover internal standards for painting, plating, etc... Each one of those WTDocs could potentially be associated to hundreds or thousands of WTParts. Which seems like it will quickly get clunky and hard to manage...Questions I have:Do you currently make associations in the above case?If so, what permissions are you giving users to be able to associate WTParts to the WTDocument? The document is at released and we don't want everybody making changes to it...Okay, I did some testing with my regular user account and was able to associate the WTPart to the WTDocument at Release. So this may not be an issue.Do you have an alternate practice instead of associations?System is Windchill 10.1 m040-marcTriMark CorporationCAD / PLM Systems Manager
Hi.I need run some code in Windchill to update objects. I need start this task at specified time and rerun it in some period.So i tried to use java.util.TimerTask implementation.Some code example i used:public class MyServiceManager extends wt.services.StandardManager { private static Logger LOGGER = LogR.getLogger(MyServiceManager .class.getName()); public static MyServiceManager newMyServiceManager () throws WTException { MyServiceManager instance = new MyServiceManager (); instance.initialize(); return instance; } @Override protected synchronized void performStartupProcess() throws ManagerException { try { /*some code to init firstTime and period*/  
My DBA and I have a trial version of 11.0 specifically for the MSG-3 module. We are trying to convert a database and this is not working at all. Is there anybody knowledgeable on the conversion process or have some kind of actual documentation of this?
I have been testing a system with PDMLink 11.0 M010, and I applied CPS4 awhile ago because I had read the FAQ about CPS which states "Customers are strongly encouraged to schedule regular CPS updates...". Applying CPS4 has left me unable to update to 11.0 M020.While attempting to update to M020, I finally found the installer log file in the system %TEMP% folder, and the installer log notes that only M010 installations up to CPS3 are compatible for update to M020. Surely, this must be a mistake, I thought. Oh, no, it's not.I went and downloaded the latest Supported Upgrade Paths document from 11/29/2016, and sure enough, M010 CPS4 and CPS5 are not supported for update to M020. Furthermore, I see that there are A LOT of dead ends in the supported upgrade paths. If you've been patching a 10.2 M030 system with the latest CPS, you're probably in trouble without an old backup to which you can revert.The Release Notes for the CPS and the Update Existing Installat
Is this possiable? I thought I have seen a few presentations the last two years at PLanet PTC talking on how to do this. Any input would be great.
Hey there WC gurus, I've worked in different CAD/CAM packages before that would allow multiple sessions to run without tying up additional licenses. This would allow you to be working on multiple projects at a time. Especially when loading a model, updating or saving takes a while, it's nice to be able to work on a lower end project like updating some hardware or adding some finishing touches.If there is a way to allow this in CREO 2.0, this would be great.We use network floating licenses here.I know that if I check out a license, I can run multiple sessions as long as I'm not connected to the network. Thoughts? Thanks in advance. - Brian
With PTC Navigate View, your talented engineering team no longer needs to manually access your PLM system to find and share the latest engineering information with others. Now they can do what they do best, develop superior products faster. Want to see how easy PTC Navigate is to use? Why not start your own 15-day free trial, and experience: Easy data access. Single source of truth. Just imagine how powerful it would be for your whole company to have a single window to all of your product data? And, what if your supply chain could see through this window too? Try PTC Navigate View for 15 Days Now! P.S. Note to all Windchill 10.2 users out there: PTC Navigate works OOTB with Windchill 10.2 and higher - no need to upgrade!
Hello guys,After installing the PTC Navigate default I am seeing the Document, Part, CAD Design Apps.How can I see the source code for created app's ?Thanks,Hemanth kumar
The Clients gadgets provides you a view of the Browsers, Operating Systems and CAD clients being used by your users to access Windchill.Peer Reports gadgets provide you with a breakdown of the Database and Windchill Server Operating System vendors used by Windchill customers.Stay tuned for additional enhancements around these gadgets providing drill down views with detail information on usage metrics, historic trend data and device information.
If your company has set up Windchill with WTParts and publishes EPMDocuments both on Checkin and during the Release workflow this behaviour may lead to incorrect data to be Released. I will present two use cases that describe the problem. While the first is easiest to reproduce it leads to no critical errors but could still be seen as incorrect behaviour. The other causes non-latest data to be released.TL;DR: The published representation of an EPMDoc when its WTPart has been iterated past latest "built" configuration is copied to non-latest WTPart. PTC states this is "working according to spec". Should the spec be treated as a bug?Settings in wvs.properties:publish.copyrepresentationsforward=true (Representation should be copied forward to the new iteration)publish.copyrepresentationsforward.restrict=false (Representations for WTParts should be copied forward to the new iteration)Use case 1:Create a CAD model with WTPartWait for publishing to completeIterate WTPart without EPMDocumentP
We are using part configurations and part instances to track serial numbers of high value items in our assemblies. I would like to have an attribute on the instances for some general notes. Currently this is a global attribute which I have added to the 'Part Instance' type, it is added to the edit layout, the visibility is set to read/edit, and the policy administration gives the 'modify' permission to users. It correctly shows the attribute on the item information page. However, there is no edit option on the action dropdown box on the part instance. There is no checkout/checkin for these type of objects either. How can I enable a user to be able to edit an attribute? Attached is a screenshot of the attribute setup and layout for this type.
Dear Windchill Users,We are planning to upgrade from Windchill8.0M030 to mostly 11.0 but before that facing the following error in new Windchill document creation.New Document creation error:For new active products as well as for products for which new document creation was working in the past, currently the new document creation is not working (New WTPart creation and checkin is working fine)Create a new WTDocument in the PDMLink folders using the following menu and upload a plain text document.ERROR:There is no trace in the Method Server log after this error (log attached) This was working in the past. Please let me know why a library is required if there is an active product and if this is a client related issue and how it can be solved.Thanks,AmolAlicon Group (Silicon Meadows Design Limited)
Hi Fellow Windchill+CAD users,Have created a new product (as per our business processes) and workspace for it and also have created and configured vaults and vaulting rules for it (Details attached)For upload of a new ProEngineer CAD part (without any geometry) on a client machine getting the following error: "A problem on the server prevented upload. Please contact your system administrator."Attempted the same thing on the Windchill server(which has ProE) and getting the following error: "Upload of Pro/Engineer model files failed. Please check the designated upload cache folder is correctly configured."Attached is a pdf document for the steps taken to debug this issue both on the client and server end including vaulting configurations. Out of your experience- please let me know what needs to be changed/configured.Thanks in advance!Windchill8.0M030+Wildfire 3~AmolAlicon/Atlas Castalloys(Silicon Meadows Design Ltd)
I am trying to backtrack tasks done by a user to clarify a scenario.Is this possible with site admin access?I am supporting Windchill and the user seems to be difficult to contact.Pls provide a solution ;I could reset his password and backtrack but that does not seem like a feasible plan.