Hi, I couldn't find any information in the documentation about this. Is it possible to enable the "View ERP part details" function in the UI without using the Tibco integration tools for Oracle or SAP? We're using a custom integration tool to our ERP system (Microsoft Dynamics) and it would be really useful to have costing and stock information available in Windchill for the engineers. Has anyone managed to get this working for any other system than SAP or Oracle? Thanks in advance!
Currently the title display is "Change Object Type - OBJECTNUMBER, CAGE CODE"The desired title display is "Change Object Type - OBJECTNUMBER, OBJECTNAME, CAGE CODE"Windchill PDMLink 12.0.2.5Similar to how WTDocuments and WTParts display the information in the title, only without the requirement for revision. I was unable to find any preferences that address this
How to implement Name suggested box in Windchill 12.1 API supported.
Hi , I'm trying to achieve below auto suggestion example with my IBA values , could you please extend your support here ? Thanks, Vishvanatha Originally posted as a new reply on this topic.
Hello, If we don't link the work flow to basic lifecycle template which automates the process then, how the objects having basic life cycle linked are get promoted? Br, Sandeep C.
Anyone know of a way to add NAME to the top of an information page in addition to the other attributes displayed?
Hello All,Greetings of the day..!I have installed windchill 12.0.2.7 as target in my system.trying to install WBM 12.0.0.0 as per the below compatible matrix But my problem is, I am not able to locate WBM as stand alone component in PSI. ( Copied all wbm files to stagging area)Please help me on this. Br,Sharath
Based on the soft type selection need to drive the attribute like get the next part sequence number
I have a question, does the WWGM exist to manage catia v6 3dxml formats?
I am using Windchill PDMLink Release 12.0 and Datecode with CPS 12.0.0.0I need instructions on how to handle components in assembly without a geometry (e.g. paint, oil, tape,...). I found some examples in Internet that Creo handles this through Bulk items, however I was not able to create different quantities between multiple assemblies driving the quantity from CAD. In SOLIDWORKS this is possible to handle using Virtual Components, however even enabling virtual components in Windchill the result is not achievable.
We have an Agriculture equipment OEM with BOM consisting of 4000+ components across multiple levels. We are working with effectivities to capture BOM as per production cut-in dates. The situation is complicated by the production planning's requirement of implementing ECNs out of sequence, thereby the revisions are jumped to assign effectivities: i.e. If I have a BOM "A1" with following parts A1 (Rev A) A1 (Rev B) A1 (Rev C) - P1 - P1 - P1 - P2 - P2 - P3 &nb
Hi, Is there any way to view the total check-out time for a part, drawing, or assembly in Windchill? My intention is to approximate the modification time taken for each part or drawing ThanksBony Antony
Hi all, I'm looking to add a custom action (an alert to get users confirmation to submit request) on the Finish button of a Wizard in windchill. Could anybody please help me with the snippet or any samples you've tried?Many thanks in advance.
Hello community,We're in discussion with a customer about SQLServer licensing for Windchill Risk and Reliability.There are 6 users.Customer argument is: if the application only uses a user for db connection, I only have to pay for 1 SQLServer licenseOur argument is that customer should adquiere as many db licenses as named users using the application (6).There is no official answer from PTC to helps us with this kind of discussion, because they consider that we should discuss it with Microsoft/OracleCan someone help me? any bad experience wtih compliances with Oracle or Microsoft?Thank you very much in advance. Maite Farreny
I am having issues with a new drawing file I have created. When I try to check-in the drawing, it errors out saying "A document with the filename XXXXXXX.drw already exists in a restricted context. Cannot change the filename of the document with filename "XXXXXXX.drw." To remedy that and save my work I had saved it as "XXXXXXXa.drw" so that it would at least get uploaded and checked in. When I search for the name that is in a restricted context, nothing shows up. Nothing exists because it is supposed to be a new part. Is there some reason I would need access to a restricted context in order to see the filename in question? Why would I need to create a filename for a file that shouldn't exist to begin with and doesn't exist when I try to find it?
HiWe want to update secondary attachments using REST, we have EPM document number, how should we do it?And how should we fetch the wt doc data from epm?
Hello all, when changing WC12,0 from HTTP to HTTPS/SSL what are the necessary steps for Creo Parametric clients? Is it necessary to upload or checkin everything before switching to HTTPS/SSL? And do we need to create a new local cache after switching to HTTPS/SSL ? Thanks and regards Jochen
what is the difference between manual rehost and run rehost through utility ? if it is can someone provide general steps for manual rehost ? FYI :- i viewed rehost guide but i could not understand clearly
I want to customize the version synchronizations for the part, cad and drawing data we use in windchill. I don't want to do this manually. Is it possible to create a flow for this process and take part data codes from users in this flow and synchronize these codes to the most current version in the workflow? If we do the version synchronization process in the workflow, will there be a problem in connecting the data with each other?
I was wondering if there is any load file available to load custom queue
While doing upgrade in pre-upgrade activity on importing the source ldap only I came to know that my baseDN value is wrong , that is while installing windchillds itself i made mistake by giving baseDN as cn=Windchill12.1,o=XXX instead of o=XXX Is there a way now to change the baseDN value and continue on my upgrade ? if so steps for that ?Thanks in Advance
I am trying to create a report that contains any change tasks or problem report currently assigned to users that are disconnected. I found this https://www.ptc.com/en/support/article/CS178728 but am having issues bringing in the problem report and/or change request/notice tasks.
Hi All,After various troubleshooting we were able to configure Custom AutoCAD worker to generate pdf.Now we are trying to create publish rules to stop publishing on check-in.It should only generate on specific state and manual creation of representation.Attached is the script we tried however it not working.Added AUTOCAD to publish.usesPublishRules in wvs.properties.Any suggestions would be appreciated.Thanks.
I am using Windchill PDMLink Release 12.1 and Datecode with CPS 12.1.2.1Hi,Upgrading from WC 11.2 to 12.1. Reaching the step of launching upgrade manager. But now upgrade manager freezes "template migrator to updatexml tag for principal reference" . Cannot find any interesting error message in logs but not sure there is any progress : it has been running for over 48 hours now.Checked resources and allocated memory which look okI found 2 articles almost pointing to the same problem for Windchill 12 but it is not exactly the issue i am facing now Any advice is very welcomeNo error message, just staying on stage :- template migrator to update xml for principal referencefor days. Thanks
I am using Windchill PDMLink Release 12.0 and Datecode with CPS 12.0.0.0 Search" -> "Latest Version Search" has been set to "Yes" in the preferences, but in the search results, the old version will be searched out; after analysis, the search for parts whose "Specification" attribute is "A1" is the largest and latest If the attribute of version E is not "A1", but the "specification" attribute of version D is "A1", then version D will be displayed in the search results. The desired effect is: if the property of the largest and latest version is not "A1", the part does not need to be displayed in the search results. -------------------------------------------------- Translated text from Simplified Chinese to English using google translate. By Community Moderation team. Subject: 高级搜索功能对最新版搜索有问题 Body: 首选项中已经设置了“搜索”-》“最新版搜索”为“是”,但是搜索结果中,会将旧版本搜索出来;经过分析,搜索“规格”属性为“A1"的部件,最大最新版E版的该属性不是”A1",但是D版的“规格”属性为“A1",则搜索结果中显示D版本。期望的效果是:如果最大最新版该属性不是”A1“,则搜索结果中不需要显示该部件。 -------------------
Already have an account? Login
No account yet? Create an account
Enter your E-mail address. We'll send you an e-mail with instructions to reset your password.