Skip to main content
Apr 14, 2018 2:18 AM UTC
Solved

How to connect Industrial Connectivity to Thingworx

I have installed tx 8.2 and Industrial connectivity 8. I have configured all pertain to tx in Industrial connectvity project properties but still Im getting some issues with WS connection. Can anyone face the similar issue? Pl help me to sort this out.

 

 

VelkumarAnswer
Apr 16, 2018 5:57 AM UTC

Hi @pselvaraj-1,

 

Can you try to disable encryption value to 'yes' and check ?

 

Regards,

Velkumar R

 

3 replies

Apr 16, 2018 5:57 AM UTC

Can you try making disable encryption to "Yes" in properties of thingworx in kepware console ?

VelkumarAnswer
Apr 16, 2018 5:57 AM UTC

Hi @pselvaraj-1,

 

Can you try to disable encryption value to 'yes' and check ?

 

Regards,

Velkumar R

 

Apr 16, 2018 6:13 AM UTC

Appreciate your response.. It works.. Thanks!