Hi! im new to thingworx and we are trying to create a drag and drop planer for or production with machine integration. Is it posible to code a ui in js and use thingworx for the backend or is it posible to make somthing like this in thingworx. we want to be able to se what is producing in the macine both art:nr and amount.and plan whats next and whos responsible for the machien via drag and drop like a canban board. has anyone done this or have any tips and trix on how to do this
I Want to set group name programmatically through service of Resources->InfotableFunctions-> Services->TOJSONI need standard service code to do programmatically. Please check the below screen shot
Hi community, I am trying to visualize in a grid or in a text field the data info after having clicked on a data point on my combo chart. (Chart Type = Line).I have already bound the selected data from the chart onto a grid, But I only see the datashape of the service on the grid instead of seeing data that I have selected. Does someone know how I can go about this? Regards,
I have used a validor to check textfields text are empty or not and if not empty then i am executing a service because validator will return TRUE otherwise i show message with status message FUNCTION to show that please enter the text into fields but it is not working. if i normally write output= true or false then only it works. can anyone please guide me in this regard. I have put a screenshot of bindings and my parameters also please have a look into it. I am using Thingworx 9.3 let Output = true; // Initialize Output as true // The isValid function should accept a single parameter to check. const isValid = (param) => { return param !== null && param!=="" && param.trim() !== ''; }; try{ // Check each parameter individually if (!isValid(emailAddress)) { console.log('Invalid email address'); Output = false; } if (!isValid(firstName)) { console.log('Invalid first name'); Output = false; } if (!isValid(lastN
I have a service takes infotable as an argument and gets some data in the form of a datashape infotable for a piechart which are just 2 counters "open" and "closed" being displayed on the pie chart.This is the code for the service for a better understanding: let result = DataShapes.ex_NumberWithLabel_DS.CreateValues();let buckets = { OPEN: 0, CLOSED: 0};let localizationstate = Resources.RuntimeLocalizationFunctions.GetEffectiveToken({ token: "ex.mu.disposition.IssueState.CLOSED",});for (let i = 0; i < objectData.rows.length; i++) { let row = objectData.rows[i]; if (row.workflowStatus == localizationstate) { buckets.CLOSED++; } else { buckets.OPEN++; }}result.AddRow({ label: "Open", value1: buckets.OPEN, DisplayField: Resources.RuntimeLocalizationFunctions.GetEffectiveToken({ token: "ex.mu.disposition.IssueState.OPEN", }),});result.AddRow({ label: "Closed", value1
Hi all, I would like to copy my string from thingworx to my clipboard. I have found 2 ways of doing so in javascript.1. .execCommand("copy");2. navigator.clipboard.writeText the issue is that thingworx does not support these 2 methods because it is a client-side operation.How can I incorporate my custom JavaScript code in my mashup? What are the steps? My ultimate goal is to copy text from a mashup to a clipboard.Best Regards
Using Thingworx version 9.4.1 on a high availability (HA) cluster.We're building a Thingworx app to display historical Thing data using the Grid widget in a mashup. The data is streamed from a Kepserver and saved in a Value Stream by logging the Thing properties. The mashup uses the "QueryPropertyHistory" service to pull a specified time period of data for all logged properties (currently only allowing data to be queried earliest to latest-"oldestFirst"=true). We also provide the option to export the queried data to csv file using the Data Export function. We just found a problem with the Grid widget that I'm looking for help to overcome; the Grid seems to be automatically filling in all empty BOOLEAN-type data cells with "false". This is a problem because the actual value of the property could have been "true" at the time queried. I replicated this issue by manually setting two booleans, let's call them "Bool1" and "Bool2" (shaded RED in screens
Hi All,There is a requirement from customer to provide the access to admin user to do the following activities at runtime:Dashboard Management: create/edit/delete dashboardTask Management: update the progress of task manually which is getting updated automatically by a formulaPrompt Management: Create/edit/delete the prompt messages and add those prompt message to a particular rolesBusiness rules Management: Create/edit/delete the business rules which are related to do aome automate operation. Will it be feasible to do the above activities in ThingWorx at the runtime?Thanks in advance for your help
How to configure Thingworx AMU alarm to not trigger when machine is manually shut down and value (ie. voltage) becomes 0 as expected? Kepware is being used in this case as well if relevant.
The quality tag in Kepwere appears to be showing a Bad tag, while the thingworx shows a good tag. Why is this the case, and how can this be fixed?
Hi, All Now I'm working on Thingworx9.2.0. [Need your help] On Grid or AdvanceGrid, I want to copy a selected cell to the clipboard, like in Excel. This means that I do not want to edit a cell, only reference to prevent incorrect entry in cell manipulation, Regards,
Hi, when trying to install KEPServerEX I'm getting the error:"The Installer was unable to find required root certificates" Do you know below mentioned instructions on installing root certificates incl. which are the relevant ones? ThanksMarco
I would like to retrieve a list of all my industrial connection Things and output a list of them. I need code to achieve thisIn this case ThingWorx Kepware Mi... should be listed.
What are your experiences about TWX 9.5?I'm very surprised, because if there were some fields to be filled, usually they had "natural" labels/description, like "Enabled", "Description", "Active", "Published".But new fields are labelled like: "tw.form-labels.deprecated", "tw.subscription-editor.labels.sequential-events",(attached printscreen was taken in one of Things / General Information tab). For me, it looks like names of language tokens instead of their values. Is that intented use? Global bug? Something local on our server?
Hi All, My requirement is for TWX HA architecture. I checked the below link from PTC support. https://support.ptc.com/help/thingworx/platform/r9/en/index.html#page/ThingWorx/Help/ThingWorxHighAvailability/OverviewOfThingworxHighAvailability.html# I have a confusion that whether Apache zookeeper and Apache Ignite will be installed on each server node along with Thingworx Foundation application or These two will be present on a separate server from the Thingworx Foundation nodes and maintain the HA architecture. Thanks for the help.
I am using the Data Logger plugin to send machine status to a mySQL server.I have machines that are offline but it is still sending a value into the database. for example, in the screenshot here, PARR-LINE-L sends CycleCount and Status to the database. it uses numeric ID 1.it is sending in the quality as 0 meaning its quality is bad but also sending in the production count of 561. when i check the live data, the quality is bad because the machine is off but the value is marked as unknown. Why is it sending a value of 561? Ifi delete the datalogger group for that machine and then recreate it it seems to work for a while and then goes back to doing this.
Now i know we can listen on thing single property value change in a Subscription , but i want to listen thing all property value change in Subscription, i have to create many Subscription with all property .Is there any way i can achieve this with single Subscription?
Hello everyone, I have a PLC Tag with a 32-bit float address (400188). When I read this using simple Modbus, I obtain a value of 15104753. However, when I configure the same in Kepware, using the float data type with the same address, I see a value of 15116893. I have tried various configurations, but the values still do not match. Please refer to the device settings and suggest a solution for the issue. Thank you!
Our factory has a remote monitoring system with a Kepware based setup utilizing DA (Data Access) method to transfer the data collected from the devices to WinCC. The Kepware version in use is 6.13, and each Kepware instance contains 12,000 static tags. The device's communication interfaces include TCP/IP and RS232.We plan to develop UA (Unified Architecture) clients in the cloud while keeping the existing system unchanged. This UA client will subscribe to data from the existing Kepware as a second remote monitoring system. However, we currently face the following problems:Some data points from the same device can be successfully transferred to the UA client, while other data points cannot. (Data transfer to WinCC via DA works fine on all data points.Data transfer from Kepware to the UA client frequently experiences interruptions, and only restarting the UA client resolves the issue.The main challenge is that the data transferred to WinCC via DA is complete, but the data received via UA
The double-click event is missing in ThingWorx 9.4 version, and I use that event extensively in my application. Please suggest an alternative that I can apply to achieve the same functionality.
How do I setup a trigger so that the Datalogger only log data when the trigger bit goes High, or low, but not both? I'm getting double data because it triggers on change not rising or falling.
While Installating the KepServerEX in my System and Getting an Error in Windows Installer Wrapper.Below is the ERROR Message.Create Process failed (-1073740777) , Please rerun Install.Please Help Us, Thanks in Advance.
We have a Thingworx 9.5 and Influx 1.7.9.It was working fine for a very long time. Recently, the connection is not working as expected. We are getting following message from Influx log. tcp.Mux: handler not registered: 71. Connection from 127.0.0.1:52517 closed In Thingworx,[O: c.t.p.i.InfluxdbDatasource] [I: ] [U: Administrator] [S: ] [P: ] [T: http-nio-8080-exec-9] Data Source thingworx connectivity test failed! with [2,002] No connection. Contact the administrator. can you someone help us? Influx is running with following cmd: influxd.exe -config "C:\influxdb.config"the influx.config filereporting-disabled = false bind-address = "127.0.0.1:8086" [meta] dir = "C:\\Influx\\influxdb-1.7.9-1\\influx_data\\meta" retention-autocreate = true logging-enabled = true [data] dir = "C:\\Influx\\influxdb-1.7.9-1\\influx_data\\data" index-version = "inmem" wal-dir = "C:\\Influx\\influxdb-1.7.9-1\\influx_data\\wal" wal-fsync-delay = "0s" validate-keys = false q
Hello,is Icon alignment in button is possible? in previous version of Thingworx 8.x, ICON on button can be aligned, but there is no option to align in 9.x.is there any possibility with CSS or any other workaround? Thanks,
Hi,I would like to create my own custom widget, but I'm a bit overwhelmed.I've seen there are different options to create a widget (e.g. with Eclipse, with Polymer or Lit, ...)Does anyone have experience with this topic and can tell me how to best start and which variant is the best? I thought it would be best if I could integrate existing ThingWorx widgets (buttons, ...).Unfortunately I didn't find much information about it, and almost no current information. And are there any example projects or finished projects for custom ThingWorx widgets somewhere? Thank you!