Recently active
KEPServerEX 6.15.132.0We have 8 Allen-Bradley Compact Logix 5300 PLCs connected on individual channels using the Allen-Bradley ControlLogix Ethernet driver via a wireless Moxa Gateway device. We also have 4 Siemens S7 PLCs that are configured, but are currently powered down and offline. These devices have been connected for almost a year and working without issue. This morning all of the tags on all of the connected devices began showing Bad (Out of Service) tag Quality. Nothing has changed on the KEPServerEX side that we are aware of. The KEPServerEX event log doesn't show any errors, just a few warnings where devices that are not online have been automatically demoted, and auto-promoted to determine if communications can be re-established.We have restarted KEPServerEX and rebooted the Windows 2022 VM Server that KEPServerEX is installed on several. We can ping all of the connected devices and can Telnet into TCP/IP Port 44818 on all of the devices. We disabled all of the devices exce
1) Top diagram is work properly before. Due to client's decision and to avoid the data lost because of client/server certificate need to renew every 3 years. we are agreed to change the security policy to "None"2) I have completed change the security level to "None" on the UA sever side. I have perform the loop back test and it's successfully (re-create the channel to connect locally).3) When I want to change the security policy from "Basic256Sha256" to "None". the setting on the UA client keep fall back to "Basic256Sha256" once I click the Apply and OK button.4) I tried to disable the tag scanning and configure, the result still the same.would it be the Authentication issue? default OPCUser issue? the log of the configuration HMI is showing i'm the administrator. seem like I can't update the security setting on UA client.
Everyone is talking about Generative AI, Large Language Models (LLMs) in particular. They are being used to provide Customer Service assistance in Chatbots, automate writing code in software development, summarizing long articles, documents, and data stores, among many other use cases. LLMs have the ability to ingest huge amounts of data, process queries related to that data, find patterns, and provide answers to natural language questions asked of the model. Could LLMs be used to provide greater insights into factory floor operations? The answer is most definitely yes! And ThingWorx can be used to facilitate this capability. ThingWorx enables connectivity to sensors, systems, and databases on the factory floor to monitor and analyze operations. Linking ThingWorx to an LLM establishes an AI Assistant capability that can provide personnel with valuable insights on the floor that can greatly reduce downtime and increase overall productivity.A new Best Practice has been developed tha
I'm trying to communicate CompactLogix L-18 ERM QBFC1 (firmware version 20) with Kepware (V6.13) and facing one strange issue.If I add the tags manually, I'm getting bad quality data in Kepware. If I try to add tags using automatic tag generation, I'm able to get few tags with good quality data but not all the tags present in the controller. Using .L5K file option, I'm able to add automatically all the tags present in the controller but data quality for all the tags is showing bad.Please help.
Hi, I have set up a number of temperature/humidity hardware controllers to a KEPserverEX.These hardware controllers will have to be powered off from time to time when the hardware is not being used.The client is a log software that automatically generates monthly data log files and requires noadministration.When the hardware is shut down it will generate a fault in the KEPserverEX event log and the client will time out on these OPC channels. Client log interval is 10 minutes with a scan of 2 cycles/s and channel. If I use the Auto-demote in KEPserverEX will the client receive anything else but a non response and time out on each request made to a non powered controller? I am open for any suggestions but particularly interested in the Auto-demote function. Would the Auto-demote add anything positive to my timeouts or is there a better way to handle this state? I am using KEPserverEX v6.9 and protocol Modbus RTU serial using Ethernet encapsulation.
I have a Thingworx 9.1 instance and am looking forward to upgrade it to 9.7. The instance is using the SQL DB. And we are planning for migration upgrade.What would be the easiest way to do this?1. Should I Upgrade to an intermediate version before upgrading to 9.7?2. Should I directly install 9.7 version in the new server and export the custom apps from 9.1 and then import it to 9.7?
I have an output from my SQL database saved as an InfoTable in ThingWorx (I've already filtered the timestamp before extracting it). How can I average all of the data in my InfoTable? I couldn't find a way to extract the data into an array (if that's even possible).
Hi, I am very new to thingworx. I created a very basic mashup with a form where the user can enter data. What I don't understand is how to ensure the data entry is saved somewhere. How does this work in thingworx? I would like the form to be saved somewhere once its filled out with a possibility to edit in future if needed.
I have parent mashup and 2 child mashups. I am showing the child mashup as pop ups.The flow of pop up is1. A button is clicked in parent mashup and child mashup A will show up.2. A button in child mashup A is clicked and child mashup B will show up without A closing.3. A button in child mashup B is clicked to update values in A and close mashup B.4. Mashup A is present after closing of B but data did not update real time. How to enable refresh real time for mashup A?
Hi is this topic solved?? Help need because I have the same problem. I have parent mashup and 2 child mashups. I am showing the child mashup as pop ups. Child mashup A has navigation button to child mashup B. When I click a button in Mashup B, it will close. Now, I want the child mashup A data to refresh. How do I do that?
We had accidently built custom extension using java 17 whereas the environment was on java 11. Upon importing this extesnion on ThingWorx the environment was not coming up and below error was observed in tomcat logs: java.lang.UnsupportedClassVersionError: com/thingworx/extensions/sshExtension/SshServerThing has been compiled by a more recent version of the Java Runtime (class file version 61.0), this version of the Java Runtime only recognizes class file versions up to 55.0. Removed the extension entry from postgresDB by deleting the corresponding entries from table extensions, extensionpackage_model and model_index after this the environment became accessible. Also, the entry was deleted from thingpackage_model and widgel_model.Post that also when we are trying to import the correctly build extension its giving below error:Unable to delete Extension zip file from storage. This is likely due to other errors: [1,018] Data store unknown error: [Error occurred while accessing t
Hi, We have a request to be able to print the page when a button on the Thingworx Dashboard is pressed. I was checking, if possible, with the HTML Text Area widget, I was trying with below code and it was not working: <!DOCTYPE html> <html> <head> <title>Print Page Example</title> </head> <body> <h2>This is a sample printable page.</h2> <p>Click the button below to print this page.</p> <button onclick="window.print()">Print This Page</button> </body> </html> Thingworx Version: 9.7Thanks,
Hi, I followed a couple of Articles from the PTC Knowledge base, and I was not able to get the Dashboard printed as a PDF with the press of a Button. Initially, I tried using an HTML Text Area, but it wouldn't work for interactions like button clicks or the window.print() method. I am seeking a solution to this issue.Thingworx version: 9.4 and 9.7Thanks,
I'm trying to create 3 D waterfall chart for which im trying to know if thingworx support such 3d chart widget and also trying to understand how can i develop such 3 D widget using Thingworx extension sdk. any guidance on this topic will be very helpful for me. Using TW. 9.3
I am using ThingWorx Platform Release 9.7 and DatecodeF000We have 2 server both server facing same issue : User is unable to authenticate with legitimate passwordHere are the errors that I faced025-05-14 08:24:35.678+0000 [L: ERROR] [O: E.c.q.l.c.Logger] [I: ] [U: SuperUser] [S: ] [P: ] [T: main] Connection refused: getsockopt2025-05-14 08:24:35.682+0000 [L: ERROR] [O: E.c.q.l.c.Logger] [I: ] [U: SuperUser] [S: ] [P: ] [T: main] Subsystem WorkflowSubsystem failed to start: Could not connect to RabbitMQ: Connection timed out.2025-05-14 08:25:37.758+0000 [L: ERROR] [O: E.c.q.l.c.Logger] [I: ] [U: ] [S: ] [P: ] [T: https-openssl-nio-443-exec-16] Authentication failed: Please make sure the credentials are correct.2025-05-14 08:25:51.286+0000 [L: ERROR] [O: E.c.q.l.c.Logger] [I: ] [U: ] [S: ] [P: ] [T: https-openssl-nio-443-exec-18] Authentication failed: Please make sure the credentials are correct.2025-05-14 08:28:14.174+0000 [L: ERROR] [O: E.c.q.l.c.Logger] [I: ] [U: ] [S: ] [P: ] [T: ht
Reference from topic - Solved: How to clear/remove array in sessionStorage - PTC CommunityThanks.It is showing that sessionStorage.getItem and sessionStorage.setItem is deprecated in thingworx 9.6 version. What is the right function can be used now. Can you clarify why sessionStorage.RemoveItemis not working. I wanted to remove particular property not all values stored in session.
Hi, I need help on how to make functional/use of the Preferences Widget - ThingWorx 9.7 version. I have dragged the widget but it is not getting used at all when I am trying to click on the save the button (the button is not working) How to take the approach for this widget. Thanks!
Performed in place upgrade from thingworx version 9.3.8 to 9.5.7 and several system tokens seem to be missing. Windows server 2019 MSSQL 2019. Example screenshots below. Is there a place to download the system localization tables for english and spanish? None of the custom tokens are missing it appears to be only tokens that are system that did not exist in the version I started from.
Hi, I am using external fonts and trying to apply those on thingworx widgets.I am using font-face css syntax and able to import them.I have succesfully applied the font to all the elements of grid expect the popup that shows up when pencil icon is clicked on each row to edit the values of each row. The problem arises when trying to inspect the popup. The popup vanishes when inspect is tried to know class and part details. Please find the attached screenshot with popup on the right and the popup is part of the Grid widget. Help me with css code to update font for this popup and verify the changes using inspect feature of browser.
Hi, I have an instance where the trace logs are generating heavily, resulting in data exceeding 50GB in just a couple of hours in PROD, and the C Drive becomes out of memory, causing the entire server to crash. I need to disable only the trace logs in ThingWorx. I tried to find an article, but none have been found as of now. How can we disable the Trace Logs in Thingowrx? Thingworx Version: 9.0 Thanks,
Containerization has been a cornerstone of modern software deployment, offering well-known benefits like portability, scalability, and consistency across environments. In the industrial IoT (IIoT) space, these advantages are particularly valuable, enabling organizations to manage complex systems with greater agility and efficiency. At PTC, we recognize that while containerization is not new, its application in IIoT continues to evolve, and our platforms—ThingWorx and Kepware—are designed to help you harness its full potential in practical, impactful ways. ThingWorx: Streamlining IIoT with Containerization ThingWorx has supported containerization for some time now allowing users to build ThingWorx Docker Container images and deploy applications with ease, whether on-premises, in the cloud, or in hybrid setups. This approach simplifies the deployment process, reduces configuration overhead, and ensures that your IIoT solutions can scale as your needs grow. For those already familiar wit
Hi, I'm currently using a trial version of KEPServer EX 6 for some testing and research. In my current set-up, I have a Matrikon OPC DA simulator server simulating some data for some tags. Then I have the KEPServer connecting to the Matrikon OPC simulator server via the OPC DA Client Driver, The KEPServer is used like a middleware to convert the Matrikon DA Simulator data into OPC UA protocol, for OPC UA clients to retrieve Matrikon DA simulator data. I have an OPC UA adapter that connects to KEPSever OPC UA Endpoint to retrieve the data and sends it to another timeseries historian. Configuration for kepware da client: Scan Mode: "Respect Client-Specified Scan Rate", Update Mode: "Exception:. Configuration for OPC UA Adapter: Polling (every 2 mins) Here is where I made some observations which I can't comprehend: 1. At first glance, the connection from my OPC UA Adapter to Kepware Server is fine and I continue to receive data. However, when I re
I am currently using KEPServerEX 6 demo and trying to establish an OPC UA connection with UA Expert for testing purposes. I have successfully configured a device (Omron NJ via Ethernet) and am able to browse and render the tag database correctly within KEPServerEX.However, I am experiencing the following issue:When I try to connect to the server using UA Expert, I get the following error:BadSecurityChecksFailedorThe server does not support the configured security policy "None"It seems that KEPServerEX is not allowing connections using the "None" security policy.I want to change the security policies in kep, but i cannot find any option to enable or change the supported security policies. It looks like the interface doesn't expose these controls.What I have tried:Checked and restarted the KEPServerEX Runtime.Confirmed that the OPC UA endpoint is active at:opc.tcp://<my-ip>:49320Tried changing the security mode in UA Expert to match KEPServerEX (e.g., None/None, Basic128Rsa15, etc.
Hi,I am using Kepserver 6.10 and trying to communicate with Lovato DMG610. DMG610 is communicating with NB114 (Serial to Ethernet Converter) and NB114 is communicating with Kepserver. There are total 13 devices connected. I am unable to define slave and Modbus address of DMG610 in Kepserver. Kindly provide a solution for this. I am attaching the details for further referencing.
Already have an account? Login
No account yet? Create an account
Enter your E-mail address. We'll send you an e-mail with instructions to reset your password.