Hi new poster here,Im trying to connect a Turck I/O module to my KepserverEX 6 like the subject says, but I dont know whether that is possible. I tried using the Allen-Bradley ControlLogix Ethernet as my driver , and selected the ControlLogix 5500 model for my device, but i cant seem to create tags for it. Please advise, thanks.
Hello everyone! Is there any way to use the service without any type of authentication? Every time I access the API, I need to use the Administrator account, but I would like a simpler method for access. Thanks!
Users belonging to a UserGroup cannot see data and Menus in MashUps. The userGroup is part of a organisation. The organisation has visibility of all components within the project, including mashups, things, menus, and everything existing in the project.However, users in the not-Administrators groups only partially see the components at runtime. Attached is an example of the homepage: And this is how Administrators group see the same Mashup: So, the userGroup don't see data and menus, but can see widgets, styleTheme and images. For comparison, I tried to check the permissions of the image and the menu, which are set exactly the same way (I am attaching a screenshot of only one for simplicity): Naturally, by adding the UserGroup to the Administrators group, they can see everything correctly, but this is not the solution.
@dmandersen With reference to topic (Kepware/MT-Connect) Do you know if the "Assets" is supported on the driver?
Good morning,I frequently encounter the following error when connecting via OPC-UA: Date Time Level Source Event19/06/2025 13:01:03 Warning OPC UA Client B&R | Read request failed on device. | Status description = 'The operation timed out.', Status code = 0X800A0000. Thank you.
Guess what I've been doing today. My latest one is when the installer tries to start up Thingworx service, this fails with the messages below. The installer then removes the ThingWorxFoundation folder so I cannot see what the issues were if it was a permissions issue. I am running SELinux but put it in permissive mode when running install. What's worse is that the installer build the schema for the MSSQL DB however since it failed, it did not like retrying the install since it said the DB tables existed. I had to drop and create the DB many times now. Error running systemctl start ThingWorx-Foundation: Job for ThingWorx-Foundation.service failed because the control process exited with error code. See "systemctl status ThingWorx-Foundation.service" and "journalctl -xeu ThingWorx-Foundation.service" for details. Directory already exists: /opt/ptc/ThingWorxFoundation Unpacking files [13:56:16] end ccif_start_post Directory already exists: /opt/ptc/ThingWorxFoundation Unpacking file
We are facing an issue in our ThingWorx environment with primary and secondary servers.The application log is throwing EntityNotFound errors.To resolve it temporarily, we added the missing Thing entity, which suppressed the error.However, this is not a viable long-term solution as we intentionally deleted that entity and do not want it to exist.Problem Details:We are unable to delete the Thing again — neither via the Composer nor programmatically.On attempting to delete, the application log shows an error: Unable to delete from DB.It seems the Thing is still being pinged or referenced, but we are not able to trace from where this is happening.We are unsure whether it’s an external system or internal service making calls to the deleted Thing.Is there a way to not to dig at the service/mashup/subscription level and still fix the application logging issue?
Hello, I am using Thingworx 9.6.4. I have a Combo Chart widget inside a Mashup and I would need to reduce the format of the reference that is presented on each point of the graph.In particular, the following information is presented to meWed Jun 11 2025 08:45:50 GMT +0200 (Central European Summer Time), value:1and I would like to reduce this information to2025-06-11 08:45:50, value: 1ThanksDimitri
Documenting this since I did not see anything posted or in knowledge base. Installer kicked out with the following message: [06:55:31] Installing CINC... Installing Installer dependencies... Executing yum Error running yum localinstall -y cinc-18.5.0-1.el8.x86_64.rpm: Repository packages-microsoft-com-prod is listed more than once in the configuration Package cinc-18.5.0-1.el8.x86_64.rpm is not signed Error: GPG check FAILED [06:55:34] Failed to install dependencies: Chef Client Now this package is provided by the PTC installer. I have gpgcheck=1 in my /etc/yum.conf which I think is standard or at least there is a STIG for it. Strange that this would report not signed. Its clear why its failing but I cannot understand why this was not caught, reported, written up and fixed by providing a valid signed RPM.
I am attempting to clear Thingworx from my VM and reinstall a clean 9.7 version. This is Redhat 9.2 and MSSQL DB (on different host). /opt/ptc folder was moved off. In Root home, .ptc_ccif was moved off and CINC was deinstalled. /opt/cinc has been cleared as well. This is what the bitrock installer shows: Log started 06/18/2025 at 08:38:10 Preferred installation mode : gtk Trying to init installer in mode gtk Trying to init installer in mode gtk Trying to init installer in mode xwindow Mode xwindow successfully initialized [08:38:13] ccif.projectFlavor: MSSQL [08:38:13] CCIF did not recognize an existing ThingWorxFoundation [08:38:13] Setting project.installationType as: normal [08:38:13] Detecting chef Setting variable _knifePath from which knife Script exit code: 1 Script output: Script stderr: /usr/bin/which: no knife in (/sbin:/usr/sbin:/usr/local/sbin:/root/.local/bin:/root/bin:/sbin:/bin:/usr/sbin:/usr/bin) Error running which knife: /usr/bin/which: no knife in (/sbin:/usr/s
I'm creating a bar chart in ThingWorx, and I need the hours I display in number format to be shown in hh:mm format (converted values), but I haven't found anything about this in the community or in the widget documentation. I would like help with this.Screenshot:I want the 8.22 for example being shown as 8:13Thingworx version: 9.3.8-b1504Widget: Bar chart
Hello, I am trying to install RTPPM 9.7.1. I am getting a similar error while installing RTPPM. the error says "Import Entities - Error Code: 50000An unknown error occured executing the install scriptCaused by:Extension PTC.Base failed to install" Please suggest a resolution. Reference topic: https://community.ptc.com/t5/Mfg-Solutions-Apps/While-installing-CWC-error-code-50000-coming/m-p/949338#M2754
Hi all, I'm facing an issue in my ThingWorx application (version 9.1.13-b1101) where the entire application becomes unresponsive when I rapidly switch between different menu items at runtime. It seems to happen when I navigate too quickly, before the current menu fully loads. The UI freezes completely and I’m forced to refresh the browser to recover. This behavior is consistent and reproducible, especially when navigating between menus itmes.Check All LogsApplication,Script,Communication but it should nothing.I would appreciate any suggestions on how to prevent this freeze or handle the navigation more gracefully.
I'm using thingworx 9.6.2 is there a way to copy paste values on cells of a ptcsgrid widget ? in particular, I would like to select 3 consecutive vertical cells, copy them, and paste into another position
DESCRIPTION: Thingworx service does not complete if getting a json element whose key contains only digits. STEPS TO REPRODUCE: 1. Define `test` as a JSON property of a thing2. Run the following service me.test = {"123": "456"} me.test["123"] // Java class "org.json.JSONObject" has no public instance field or method named "123" JSON.parse(JSON.stringify(me.test))["123"] // Works (workaround) ERROR MESSAGE: Java class "org.json.JSONObject" has no public instance field or method named "123" VERSION 9.1.5-b698 I'm submitting the bug report here since there is a paywall on the contact us support page and this might be a big issue since it is interpretting the text of the key of the json object as code (or at least as a literal).
Hi all, Does anyone know if using legacy widgets could cause mashup performance issues or crashing? I have an old mashup that hasn't had its legacy widgets migrated fully that continues to crash randomly. Would this be a possible reason for crashing, with this message below? The only reason I haven't migrated is because this mashup visually gets changed significantly from the legacy widgets to new implementations, but I can't seem to narrow a separate reason that the crashing occurs and don't have the issue on any other similar mashups with new widgets. Thanks for any input!
From the PTC Software Download page I can only see ThingWorx 9.3-9.5, but not any other versions like 9.6-9.7. Why is that?
We are getting lots of tag from PLC devices (40+) to Kepware. Sometimes, due to some reason the connectivity is lost between PLC and Kepware. So that we facing data loss issue. Is there any mechanism within a Kepware to address this connectivity loss? How to identify this connectivity loss from ThingWorx for all PLC devices?
Hi everyone,I’m working on a UI feature in ThingWorx Mashup and was wondering if something like the following is possible:👉 I have a layout where a picture (or model view) is shown on one side, and I want to dynamically change its size based on how I drag a divider or a panel.When I drag the divider to the left (making the picture area larger), the image or 3D model should grow (scale up).When I drag it to the right (making the area smaller), it should shrink accordingly.The idea is to simulate a sort of "zoom effect" by using the container resizing rather than zooming through buttons or manual controls.📷 Here's a screenshot for visual context:(Attached image showing the mashup and panel layout with the drag area)Has anyone tried implementing something like this before?Is it possible to bind the widget size or scaling dynamically to container resizing in ThingWorx?Or is there a workaround with CSS or JS injection?Any ideas or tips would be greatly appreciated!Thanks in advance!
I am using ThingWorx Platform Release 9.7 and DatecodeF000The new Collection widget behaves differently compared to the legacy version. When the data connected to the Collections widget is refreshed, the entire widget reloads, creating a disruptive effect. In contrast, the legacy Collection widget does not exhibit this behavior. I have confirmed that the configuration is identical for both widgets in my cases.To clarify, the data is properly connected to the widget. One of the data fields is selected as the UIDField parameter, and data is pushed to the cell via the MashupPropertyBinding configuration. However, when the data source is updated (e.g., through auto-refresh), the entire Collections widget reloads instead of just updating the data within the cells.A workaround is to bind data directly in the cell mashup, but this approach is performance-intensive and not considered best practice.
Hello We are using KEPServerEX 6.17.240. We are trying to diagnose an issue with frequent disconnects between a Siemens PLC and KEPWare, communicating over OPCUA. We are looking at the OPC Diagnostic log from View -> OPC Diagnostic and I am looking for any documentation for how to interpret these events. For example, we are continually getting these "ServerFaultResponses" (which are timeouts associated with a previous "PublishRequest". But there's really no documentation I can find to help interpret these. Some of the other logs have an actual program name in the brackets, where as this example has a seemingly random number. Is there a way to associate this number with a process? Is this number generated somehow by KEPWare or something like a ClientID from the actual OPC Client application?I'm basically looking for extra information about what some information in these logs mean, specifically for helping to interpret why we are flooded with timeouts and th
Hello! With reference to this topic i have talked with MAzak and in the new versions of the controller you can activate the CVARs, but the problem so far is y only can see the System and assets which at least in kepware we do not see the tool life/ Cvars Value, i can only see those in the XML locally
Hi all, Looking for more information on the service mentioned in the description. Mainly more information or examples on formatting for the inputs of the service as the descriptions seem limited for someone without experience on using the Analytics functions of Thingworx. Thank you!
Hello, When I run my edge, everything works fine. However, I notice a message keep showing periodically: INFO com.thingworx.communications.client.TwApiWrapper - api_requesthandler: No handler found. Returning 404 My device works fine, and I am able to run and control my remote properties and services.Is there an explanation why i have this message ? Can I remove it ? -.NET Edge 5.9 with .NET8-Thingworx 9.5.1
April 22, 2025 Hello ThingWorx community members!We are excited to announce the preview release of ThingWorx 10.0, the latest evolution of our IIoT platform for all your Industrial Data Management needs. This release focuses on delivering a powerful, secure, and intelligent foundation for industrial innovation, empowering businesses to achieve more with their IoT solutions. Powerful & Secure: A New Standard in IoT Platforms ThingWorx 10.0 sets a new benchmark for scalability and security in IoT with features like IOT Streams to enhance enterprise industrial data acccess and reliability, caching improvements to increase server scale and response times, and security updates for TLS, Tomcat, Java, and others to ensure top-tier performance and protection. These advancements make ThingWorx 10.0 the most mature and secure platform yet, giving businesses the confidence to scale their IoT deployments while safeguarding their data. Industrial Solutions: Ready to