Acknowledged

WNC Bridge and Schematics license manager not working synchronized

Please include detailed documentation such as screenshots, images or video.

1. What product and version are you running?
Schematics 10 and WNC Bridge


2. What is the problem?
License Manager for WNC Bridge from Virtual Interconnect doesn't release licenses automatically after idle timeout. When application is not in use for long period, ie.: 20 minutes, license shows still in use.
License manager should work in the same way as for Creo Schematics, license is released and return to license pool after X number of minutes. Current WNC Bridge license is just released after Creo Schematics application is closed.

3. Are you using a workaround? If yes, please describe it.
No workaround available

4. What is the use case for your organization? Describe how your idea would work in context or how it would apply to a practical situation.
When WNC Bridge is idle license is not released to server in the same way as Creo Schematics

5. What impact does this problem currently have on your organization? (Number of users affected, hours of lost productivity, etc.)
Helps reduce license denials of WNC Bridge

6 replies

Community Manager
Nov 6, 2024 10:54 AM UTC
Status changed to: Clarification Needed

Thank you @LL_9579900 for publishing your idea. However, we need more information as specified in the form you saw in the submission process. You may simply add a comment to your idea. The more details and context you give to document your idea, the better. Think about ways to educate and convince other Community members to support your idea and present your case to the product management team for consideration.

Please let us know within the next two weeks.

Additionally, I invite you to check out this topic where PTC executives explain product managers' approach to customer ideas and input for product roadmaps.

 

Please see examples of well-documented ideas:


https://community.ptc.com/t5/Creo-View-Illustrate-Schematics/Inability-of-Creo-Illustrate-to-produce-3D-figures-with-color/idi-p/977424 

https://community.ptc.com/t5/Creo-View-Illustrate-Schematics/Adding-light-and-Changing-its-position-isn-t-very-user-friendly/idi-p/977434 

https://community.ptc.com/t5/Creo-View-Illustrate-Schematics/Enhancements-for-Insets-in-Creo-Illustrate-Beyond-Magnification/idi-p/977438 

https://community.ptc.com/t5/Creo-View-Illustrate-Schematics/Explode-STEP-files-amp-other-converted-models-in-Creo-Illustrate/idi-p/977468 

https://community.ptc.com/t5/Creo-View-Illustrate-Schematics/2D-scalable-vector-symbols-with-Halos/idi-p/977477 

 

Nov 6, 2024 3:55 PM UTC

Hello Catalina -

 

Today's integration between Creo Schematics and WNC Bridge are managed with two different license managers. In Schematics we have an idle timeout of 20 minutes, when that happens license is release to the license pool.

At the same time WNC Bridge is using the license, however there is no idle timeout for WNC Bridge. While Creo Schematics is opened WNC Bridge is still consuming the license when Schematics license is already back to the pool.

Community Manager
Nov 7, 2024 9:27 AM UTC
Status changed to: Acknowledged

Thank you @LL_9579900 for your idea. Based on the information you provided, we are acknowledging it as the Community management team. This is not a commitment from the Product team. Other users may comment and vote your idea up.

Nov 21, 2024 5:55 AM UTC

Since we do not use WNC without Schematic, we should not need more WNC licenses than Schematic licenses.

Nov 26, 2024 9:54 AM UTC

Hi @LL_9579900, Hi @dvo ,

 

Creo Schematic is using a concurrent user licensing, but Windchill uses a named user licensing. So it's common for customers to more licenses on the Windchill side than on CAD application side.

What is your expected business outcome?

Regards,

Ruediger

Nov 26, 2024 6:11 PM UTC

Hello @Ruediger_Scholz 

 

In this case we are not talking about Windchill named licenses. As I explained before, Creo Schematics license manager (flexnet), has the ability to release the license after minutes it is idle (we configured to 20 minutes). After 20 minutes license is back to the pool of licenses.

When we started using WNC Bridge between Creo Schematics and Windchill, we introduced a third application/license manager for WNC Bridge. From Schematics we starts WNC Bridge that consume one license, when not in use after 60 minutes idle (default time), it should release the license to the pool, however if Schematics is opened it will never became idle, even if Schematics is idle for 60 minutes.

In this scenario Schematics license was already released to the pool after 20 minutes but WNC Bridge still shows active, unless Schematics is completely closed.