31 characters are not enough for design. This limit sometimes is driving customer crazy. For CATIA the limit of file name is 81 characters.

87 replies

Jan 29, 2020 7:18 AM UTC

Year 2020 the idea has been created 2012 there is really hard work on this enhancement.

 

Jan 29, 2020 8:50 PM UTC

In my opinion 31 characters is plenty... if you need anymore than that you should probably have a CREO swear jar.

Jan 29, 2020 9:43 PM UTC

Our corporate standard for part numbers is 7 characters. Add 3 characters for dash numbered components of a weldment and we have 10 characters.

 

Where I used to work, we would do things like hoses (modeled for an assembly) with hose_part_number-Assembly_number-Hose_Sequenece, so using the 7character numbering, that would give us 18 characters (1234567-7456321-02). With 31 characters, that still leaves us with 13 characters for designers to come up with funky names that usually don't get released since the CM team (me) won't allow those numbers in a released structure. I do allow some exemptions when justified!

 

If you are naming your parts: BigBadJohn_TestAssembly_ForMariansSpecialOneOffProject, You may want to rethink your naming strategy or move to a PDm system where the database can handle that as a description and the filename on disk can be 00acfg67eda2.

Jan 30, 2020 2:28 PM UTC

Our regular internal part number scheme is 7 characters as well.  However, our customer number can get quite long because of all the options available.  We haven't had a problem yet but there were a few close calls.  There are some customer numbers that would be longer than 31 where the customer COULD order but we haven't had that yet.  Extending the 31 character limit is a MUST.

 

I.e., this is a customer number that COULD be ordered (replace by actual letters and number of course):

XXXX-XXXX-X-X-XXXX-XXXX/XXXX_XXXX

 

The limit doesn't have to be removed.  Just increased.  40 or 45 characters should be fine?

Jan 30, 2020 3:18 PM UTC

I think the hardest part of this request is the programming involved in updating existing files.

Extending the buffer size, while might be in hundreds of code files, is the easy part.

Think of each CREO file as a mini-database with a 31 character field reserved for the part number. Next to that field is the one for version, then iteration. Now increase the buffer size for the first field and write back 60 characters instead of 31. You have just overwritten the version and iteration plus maybe more data. The file being modified has to 'move' those other fields over to allow the part number to be 60 characters long. No easy task.

 

Has the part number length always been 31 since the days of Pro/Engineer v1? I guess being on Unix originally, they didn't have to worry about the DOS 8.3 convention of those days.

 

Jun 11, 2020 2:39 PM UTC

PTC, Please take this enhancement request seriously.  This is and has been causing MAJOR problems for us especially when working with ECAD.  During the ECAD/MCAD data exchange, our ECAD library component names exceed 32 characters and we cannot match them with Creo file names because of this restriction.  This causes us to create a mapping file which is a manual process and it is VERY time consuming and prone to error.  This request has been submitted and voted on for MANY years, and there is no reason that modern software should have this restriction.

Aug 18, 2020 12:14 PM UTC
Status changed to: Under Consideration

Currently, Creo Parametric does not support file and feature names greater than 31 characters (Unite supports up to 75 characters), white spaces, special characters and mixed cases.   This limitation also impacts areas within Creo; such as dialogs, relations, family tables, model tree, etc.  As a result of this limitation, names are truncated, or not allowed, which presents a major usability issue raised by users.

 

PTC is aware of these limitation and is currently researching efforts to remove the naming restrictions in a future release. 

 

As part of this effort, PTC will hope to deliver a solution that will support names up to 179 characters, spaces and special characters.  The plan will be to remove these restrictions in file names, model names, features, parameters, Model Tree, dialogs, family tables, layers, toolkit, Unite and all other areas impacted by this limitation.

 

Regards,

Mark Fischer

Sr. Director, CAD Product Management

Aug 18, 2020 12:21 PM UTC

@mfischer This is great news.

 

I hope this limit will also be extended for documents in PDMLink.

Aug 18, 2020 1:45 PM UTC

@mfischer , Thanks for the update and good news!  I hope you keep this idea updated once you figure out which versions this will get implemented in.

Jul 30, 2021 3:51 PM UTC