Regeneration is important. But...

 

Currently, when we hit Ctrl + G in an assembly, it will regen every single parts (regardless of repeat items), regardless if the parts have been modified (check it in the message log).

 

It will not make any difference if the assembly are below 100 items.

But in a main assembly with lots of sub-assemblies and repeated components, it will be waiting ... and waiting...

 

Would be very much appreciated if we have this option so that only modified parts or relocated components need to be regen.

 

Thank you

3 replies

Nov 4, 2019 10:45 AM UTC
Hi Eileen, you could use this config.pro option: regenerate_read_only_objects no
Nov 5, 2019 2:47 AM UTC

Hi Trebla, thank you for the recommendation.

I had tried out. It works well for components had been "Locked" in the workspace.

But for those "Not Locked" and no modification, it will be regen again.

Another option to work faster.

Thanks.

olivierlp
Community Manager
Jan 3, 2024 5:21 PM UTC
Status changed to: Archived

Hello,

We are archiving your idea as part of a general review. This action is based on the age of your idea and the total number of votes received, as per this announcement.

You can always post a new idea with all the details required in the form.

Thank you for your participation.