Skip to main content
Jan 7, 2026 9:09 PM UTC
Acknowledged

Provide API support in Creo Parametric for SSO authentication in Windchill

Related products:Creo Parametric

1. Describe the Problem

Creo Parametric currently does offer API support for SSO authentication with Windchill (reference Articles CS255647 and CS454223).


2. Are you using a workaround?
No - per Corporate security policies, no bypasses or workarounds are permitted for SSO authentication.

3. What is the use case for your organization?
Our company uses SIGMAXIM’s Smart Design Server and Smart Assembly products for an automation that provides unattended creation of Creo assemblies and export of that data in various formats based on input from a separate customer-facing application. We recently implemented SSO authentication in Windchill, and the automation can no longer operate unattended due to the lack of API capability for the SSO authentication when Creo runs with Windchill connected.

4. What impact does this problem currently have on your organization?
This is very painful for the team that supports the automation, as user input is now required to authenticate every time Creo needs to be opened or reopened on the cloud server to process the jobs managed by Smart Design Server. The automation now requires constant monitoring to ensure that authentication can be completed when required.

6 replies

1-Visitor
Jan 8, 2026 7:03 AM UTC

This idea seems to be quite similar to my idea "Possibility to adopt the Windchill login credentials in Toolkit apps".

In principle, my idea is that if a user has logged in to a Windchill system in Creo - regardless of whether with basic or SSO authentication - Toolkit apps should be able to access Windchill in the session, just as the user has.

DavidCobbAuthor
Jan 8, 2026 4:22 PM UTC

Hi Domenic, thanks for the comment, I agree that there is some similarity between the ideas. I feel like the distinction is that in our scenario, via automation an unattended session of Creo is connected to Windchill with a user login that is different from the credentials that the cloud server is operating with for the unattended session, which stops the SSO authentication and requires user input for the user name and password. As noted, this isn’t supported per the referenced PTC articles. If I understand your scenario correctly, you want to reuse authentication credentials from a Creo session where the authentication has already occurred, which definitely makes sense but is a bit different from our use case. We would love to see both requests addressed!

Jan 8, 2026 6:40 PM UTC

While I'm not familiar with the Sigmaxim tools and have never testing any of this, can't the cloud server Creo instances be run using a dedicated user domain account (using RUNAS or the like)? The dedicated user account can be defined to deny log on locally everywhere to prevent interactive login (or everywhere except for the Cloud server if an interactive session is required by the Sigmaxim tools).
Also, service accounts can authenticate via SSO without an interactive login, so it may worth looking at running the Sigmaxim tools/processes under a typical Windows service account. The dedicated user or service account needs to be given the correct access/licenses in Windchill.

Community Manager
Jan 9, 2026 12:20 PM UTC
Status changed to: Acknowledged

Thank you @DavidCobb for your idea. Based on the information you provided, we are acknowledging it as the Community management team. This is not a commitment from the Product team. Other users may comment and vote your idea up.

DavidCobbAuthor
Jan 9, 2026 7:09 PM UTC

Hi Dan, thanks for your comment. My understanding from talking with SIGMAXIM is that Smart Design Server launches Creo unconnected to Windchill and uses API calls to register the Windchill server and pass the authentication credentials, which already use a service (non-person) account that has the appropriate Windchill access. The API calls support doing this when Windchill is configured for basic authentication. As described in the referenced article CS255647, the problem when using SSO Windchill authentication is that the API calls “ProBrowserAuthenticate() & AuthenticateBrowser() currently does not support Windchill Authorization through OAuth2.0 using OKTA”. Due that gap, Smart Design Server can’t pass the login information to Windchill at all, which is the root of the problem.

Jan 9, 2026 8:28 PM UTC

David,

Does the Sigmaxim software run Creo Parametric in non-graphics mode to do all it’s processing? Just curious as I haven’t seen the software before. Based on your initial description of the problem, it seems to run the GUI since your automation support team has to “login” each a job is run.

As a work around, can Sigmaxim skip/drop the Windchill registration and login process when it launches Creo? Your Creo Parametric launch script should be able to define the Windchill items necessary to start Creo Parametric associated with a Windchill instance. Any action within a WS usually triggers the SSO. You’d still need to setup the service account to authenticate correctly with SSO. Even if Sigmaxim cannot or doesn’t want to change the script, if the automation is simply pausing for the authentication to occur, setting up the service account to authenticate via SSO may still work.

As another option (read that workaround), if Creo Parametric is running the GUI, create an AutoIT script that waits for the “login” window to open, activates the window, and enters the credentials for you. We’ve used AutoIT for years to automate tasks in GUI based tools. You can encrypt the PW data, so no PW’s are exposed in any clear text files.

Good luck.

Daniel Nordin

Mechanical/Optical Engineering Tools Support

Engineering Tools, Enterprise Shared Services
BAE Systems, Inc.

E: daniel.nordin@baesystems.us
130 Daniel Webster Highway, Merrimack, NH, 03054
www.baesystems.com

Connect with BAE Systems: upload_-aW1hZ2UwMDEucG5n-3332960003491220553..pngupload_-aW1hZ2UwMDIucG5n-1424306751915494092..pngupload_-aW1hZ2UwMDMucG5n-8468873914095950410..pngupload_-aW1hZ2UwMDQucG5n-3702246551365315881..pngupload_-aW1hZ2UwMDUucG5n-8076785740191774025..pngupload_-aW1hZ2UwMDYucG5n-1116014084688384558..png