Skip to main content
Feb 3, 2016 11:06 AM UTC
Duplicate

Multiple sessions in CREO3 available

Related products:Creo Parametric

I would like to submit an idea to have a possibility to work in multiple session in CREO 3 - like it was possible in CREO 2 - which was very helpful.

9 replies

1-Visitor
Feb 3, 2016 11:13 AM UTC
Feb 3, 2016 1:48 PM UTC

Duplicate idea and it is possible if you follow the guidelines outlined in CS202061.

https://support.ptc.com/appserver/cs/view/solution.jsp?n=CS202061

Feb 4, 2016 12:48 PM UTC

Ryan Kelley‌ - duplicate?

3-Newcomer
Feb 4, 2016 1:03 PM UTC

There's no mention of Windchill here, although outside of Windchill I'm not sure what they'd be talking about.  The OP needs to clarify if they are talking about the same thing.

Feb 4, 2016 1:25 PM UTC

I'm inclined to agree with Doug Schaefer, we can't be too quick to close out Product Ideas without understanding more of the use case. Zbigniew Danielewski‌ - can you provide more clarity and answer the question of whether this idea also pertains to PTC Windchill‌?

Feb 5, 2016 6:47 AM UTC

PTC Windchill developers should disable synchronization between two separate Creo3 sessions.

In Creo2 there was no synchronization between multiple sessions and the user decided which one is to be connected to Windchill (PDMLINK) and in another one could work "standalone", for example with files stored on local disk.

If two Creo3 sessions are automatically synchronized, this situation complicates designer's work, especially on new parts and assemblies. For example, if we have created a new prt or asm (on local disc) and we would like to compare this component  with similar component that exists in PDMlink - it is not possible.

This situation very complicates the process of designing.

In my opinion there is no risk regarding data integrity affecting Windchill. Always one server/one workspace is active. In standalone Creo session data files cannot be saved to Windchill.

Feb 5, 2016 2:28 PM UTC

Yes, this issue is almost a duplicate of the one you mentioned on top of this conversation - "Multiple session of Creo3 embedded with Windchill".

We understand the idea of synchronization of data between Creo sessions while working with Windchill. We shouldn't use 2 sessions connected

to different servers or simply 2 different workspaces, to avoid data integrity problems.

But we would like to have possibility to disconnect one session from Windchill (Creo working standalone), while the other one would stay connected.

Do NOT force disconnecting both sessions. Files loaded from harddisk can't be checked-in in this mode, so the other session won't be affected.

Am I correct?

Jan 3, 2017 7:35 PM UTC

Absolutely!

May 1, 2019 8:56 PM UTC