The standard holes when you choose ISO in Creo should in fact be according to ISO.

What it looks like today Creo Paramteric 1 & 2:

ISO_holes_in_Creo.jpg

But the ISO standard are these three for a M12:

12x1

12x1.25

12x1.5

3 replies

Sep 26, 2013 3:41 PM UTC

I will vote for this only because in ISO, both methods are acceptable, however, the -standard- thread does not need the pitch specified.  You only need to specify the pitch if it is not the standard size.  What is not clear from the dialog is which one is the standard pitch.

This could be resolved with simple "STD ISO" and "EXT ISO" thread tables similar to how we use UNC and UNF.

Oct 22, 2014 12:59 PM UTC

And what about pitch into the dimension in drawing? Is this possible?

dimension_pitch.png

Mar 17, 2019 2:43 PM UTC