Skip to main content
May 15, 2025 3:41 PM UTC
Acknowledged

Intelligent Fastener Extension (IFX) to allow custom libraries that use an assembly (SEM Screws)

Related products:Creo Parametric

1. Describe the Problem

We are slowly going through our current libraries and adding them to the Intelligent Fastener Extension (IFX). We can not add our SEM screws, as they have been built as an assembly and IFX can not manage assembly hardware. 

 

jwagh_0-1747323492146.png

 


2. Are you using a workaround?
No. We are not using IFX for this type of hardware.

3. What is the use case for your organization?
We use SEM screws in most of our products. Having some hardware in IFX and others not, does not make for a robust library and process.

4. What impact does this problem currently have on your organization?
It creates confusion with process, implementation and part searching.

5 replies

olivierlp
Community Manager
May 15, 2025 5:53 PM UTC
Status changed to: Acknowledged

Thank you @jwagh  for your idea. Based on the information you provided, we are acknowledging it as the Community management team. This is not a commitment from the Product team. Other users may comment and vote your idea up.

Olivier
May 15, 2025 9:29 PM UTC

Do you buy a SEM screw as 2 parts (screw and washer) or a single part? I modeled mine as a single part as that is how we buy them.

jwaghAuthor
May 16, 2025 1:20 PM UTC

@BenLoosli 

We buy them as a single part. However, there are multiple situations where an assembly is a single purchased item. For instance, a power supply can have dozens of components in an assembly, but is purchased as one. For the SEMs, we already had a family table for screws and a family table for washers. It made sense, at the time, to just make an assembly that used those family tables in another family table.

May 21, 2025 6:29 AM UTC

Hi @jwagh 

 

I think this is a good idea.

 

But for assemblies it only will be possible to use already existing models - the assembly must exist in your database.

The creation form IFX 'on the fly' by using a template is not supported in this case.

 

A new keyword 'MDLTYPE' must be added to the *.dat file.

If this value exist and it is set to 'ASSEMBLY', then IFX will search for an assembly instead of a part.

 

The required references for the assembly constraints must be inside your assembly model. 

  • It is not possible to use an axis or surface from a sub-model

Will this fit your requirements?

 

Regards,

Oliver Gräbner

B&W Software GmbH

jwaghAuthor
May 21, 2025 1:14 PM UTC

@OliverGräbner, that works! Thanks!