When creating a BOM of an assembly which contains shared parts, the name of the shared parts in the BOM is the instance name of the last created instance of these shared parts. While in the structure browser the shared parts are grouped in a pseudo-folder and the name of this pseudo folder is determined alphabetically. I think it should be better if the BOM entry would be given the same name as the pseudo folder, or at least the option should be provided in the default settings.I know that adding a model name to a part overrules the instance names and solves this issue, but I don't want to change all my assemblies, I would like this to be default.
The Appearance Gallery should display all appearances used in the model at all times.As it is now, if the insert prompt is not below a surface/solid that has an appearance, that appearance will not be listed in the gallery.
When you set the tolerancing standard for a part to ANSI in Creo Parametric, the tolerance tables are disabled. However, the ASME/ANSI standard supports metric limits and fits tables for holes and shafts. Thus, tolerance tables function should be supported for the ANSI standard.See ASME Y14.5M-1994, section 2.2.1.
Here's a video of Leap Motion being used with Siemens software: http://www.youtube.com/watch?v=xNqs_S-zEBY&feature=youtu.be I actually purchased a Leap Motion unit to see what I could do with it and Creo Parametric, View, etc. The answer: Nothing. PTC please enable use of new controllers and other interface technology.
Currently, when Mirroring an assembly, neither Pro/E nor Creo Parametric uses a start file such as a company's starassy.asm.PTC please enable the use of a startassy file for Mirror Assembly so that it is consistent with other mirror functions.
When using the symmetry option to create extrudes, you only have the blind option available. Please add option to do the same for symmetry up to surface or selected, next, ect.....
When a datumplane are created, there often is that you have to change the defenition of it afterwards, this is working very well in Creo. But if the datumplane are used in for example an "dimension pattern" the placement tab is removed when using edit defenition on the datum plane. This should be added so there is no need to change the reference manually or by deleting the pattern, change the reference and then recreate the pattern.
please add the selection option to freestyle to be similar to the options in drawing mode and when working with facets.This will give the user more control on what he wants to select by draging a poligon on the screen. That way he can select multiple pathes in one command.
I want a function which copies a sheet (sheet 1) in the drawing (annotation) to the next sheet (sheet 2) in order to be able to adjust this and use a configuration such as shows a detail included in another position.
I want the function which fixes the position of an angular dimension in the sketch of 3D model.
When an additional element is added to a sketch, an additional element is displayed on the distant position.
When the solution to optimization is not found in BMX, the undo button may gray out and may not work sometimes.
Currently, there is no way to get to the home icon, in an embedded session of Windchill, except by clicking on Workspace, having the view refresh (which can take several minutes), and then selecting the Home icon.Please add the Home icon to Common Folders or some other centrally accessible location witout making users access a workspace first.
Currently only a PartLibrary item is protected for copying. So when you copy an assembly, everything is copied, but not your PartLibrary element, this is shared. You should be able to set such a flag for a part/assembly of your choice. For the moment there's functionality to make a PartLibrary element of your part/assembly. But after that moment, you can no longer modify it, even not an administrator. Customers often ask this functionality to make "standard parts" or "catalog parts". They don't want to make a PartLibrary part of it, because these parts can no longer be modified or revised. And when you make a normal part of it, and store it to MODEL_3D in Model Manager, it can always be copied in your Modeling session, instead of automatically shared.
Often, when I constrain something in an assembly, Datum Plane to Datum Plane, Datum Plane to Datum plane and a third datum plane to datum plane pair, Pro/E will conclude that the constraints are invalid when I click the final pair.I don't choose the Align or Mate for each one, Pro/E does. I don't choose Coincident or Offset for each one, Pro/E does.Why, then, can't it choose a combination that is Not Invalid?Idea:When setting constraints for a component in an assembly, choose default constraints that work, not Invalid, mutually exclusive constraints. If necessary make the defaults intelligent in order that this happens.WF4, M220 here
When I interrogate an assembly to see how things are constrained, if I click a constraint between 2 datum planes, the datum planes are shown on the screen. However, if I do not have Datum Planes 'Shown', only the plane will show up, not its name. If I want to know its name, I have two choices: I can 'Show' datum planes, or I can hover the mouse over the right part of the constraints dialogue and hope the tooltip pops up. 2 problems:I had the Datum Planes not 'Shown' for a reason. It's a big assembly and there are lots of them. Many of them belong to legacy parts that have the old-school layer business in them, so the do not come into session with Datum Planes hidden like my new parts do.Sometimes, the tooltip does not pop up. Don't ask me why or when, sometimes it just doesn't.Of course, if the dialogue box were designed differently, I could drag it to a different width so I could read the contents of the box, but let's not get carried away...My Idea:When I click on a constraint, light
per call C10681018 Issue Information Short Description How to set a focus to a navigator pane tab added with ProNavigatorpaneBrowserAdd Symptoms The tab added to a navigator pane via Pro/Toolkit could only receive a focus through user interaction Steps to Reproduce Use a function ProNavigatorpaneBrowserAdd ... (Please answer via email, most likely it is a gap in functionality, I want to be sure before filling up an enhancement request)Thanks. Error Messages / Warnings Reason for Closure Solution Delivered Closure Details As per Pro/Toolkit for Creo Elements/Pro 5.0 product specifications, this functionality is not yet available. There is no API currently available to set the focus on the navigator pane that was added using ProNavigatorpaneBrowserAdd(). Also is missing - the ability to remove ProNavigatorpaneBrowser tab when the browser is no longer needed...
The missing types are PRO_AXIS and PRO_CSYS. The missing types are making it very difficult to deal with any kind of 'revolve' features which would have an axis as one of ProGeomitems or with imported geometry features which could have axis and coordinate system ProGeomitems as feature members.
per call C10664404 Issue Information Short Description Customer would like to know how to determine if a user-defined parameter was locked by the user. Symptoms seems to be missing functionality Steps to Reproduce Try to callProParameterRangeGet( ¶m, &if_locked, NULL, NULL);or ProParameterIsEnumerated( ¶m, &if_locked, NULL);if_locked would be PRO_B_FALSE and return status of both functions was PRO_TK_NO_ERROR CallingProParameterDriverGet( ¶m, &drv);drv was set to NONE by the function and return status was PRO_TK_NO_ERROR In all cases the value of parameter was an integer type... The only meaningfull return status was from ProParameterValueSet which was PRO_TK_GENERAL_ERROR but this approach does not look like a good one. Error Messages / Warnings Reason for Closure Currently not supported Closure Details Informed the customer that currently no APIs available to determine if a user-defined parameter was locked.
per case C11155912Issue InformationShort DescriptionCustomer needs assistance in changing the default view settings of folder library in Creo ParametricSymptomsPro/E seems not to 'remember' folders view settings when pro/e session gets restarted Steps to ReproduceError Messages / Warnings Reason for ClosureCurrently not supported Closure DetailsAs per the current functionality of Creo Parametric settings remain only for the current session and cannot be retained in the later sessions of Creo Parametric. Customer requested to close the case and will file an enhancement request
per call C11229318 Issue Information Short Description Which ProNotify event has to be used to notify an application about layer status change in the active model? Symptoms Cannot find any mentioning of layer related events in user guide Steps to Reproduce -Change layer status-trap it with an event??? Error Messages / Warnings Reason for Closure Solution Delivered Closure Details At present there is no Notification functions defined to capture the display status changes made to a layer in part or assembly. Advised the customer to try using ProCmdBracketFuncAdd () and add call back functions for involved commands in Creo Parametric 2.0
per call C11243199 Issue Information Short Description Customer would like to know what test can be run while in Pro/MOLD mfg assembly to determine that the feature of type PRO_FEAT_DATUM_QUILT,PRO_FEAT_DATUM_SURF,PRO_FEAT_SRF_MDL, PRO_FEAT_GEOM_COPY,PRO_FEAT_REPLACE_SURF is the parting surface. Symptoms Steps to Reproduce In model tree there is an alteration on feature name : [PART_SURF_1 ...]Please see the attached image.Tried to visit surfaces of the feature or quilt->surfaces of the quilt and get their names. Nothing was there. Tried to check ProElement trees - there was no difference between features identified as parting surfaces and simple features.Also no difference in ProFeatType or ProFeatSubtype. Error Messages / Warnings Reason for Closure Currently not supported Closure Details Not part of current Creo TOOLKIT functionality.
per call C11250411Issue InformationShort DescriptionHow to set option 'Holes > Depth > Measure > By Tip' to come up as the default option for holemaking sequences?SymptomsUsers seems to be forgetting to reset 'By sholder'/'By Tip' option , burried 4 levels deep in the dialog boxes which causes metal scrap... Steps to ReproduceJust follow the intended work flow and make 100+ holes...Please do not suggest to create XML templates and use them. We know about this option.Error Messages / Warnings Reason for ClosureSolution Delivered Closure DetailsInformed the customer that it is not currently possible to have the default option set to "By Tip".
per call C11343615 - tech support suggested to fill up a 'product idea' Issue Information Short Description Is there a way to access information about ProSolid and ProDrawing models referencing ProSolid model while the later been renamed in session without scanning all models at known locations ( current directory, search path ...) Symptoms Try to rename a part model while referencing drawing is not in session and try to retrieve a drawing afterwards... Steps to Reproduce Rename a part model while referencing drawing is not in session and try to retrieve a drawing afterwards...While this is an age old problem, I was wondering if it possible to use one of ProNotify types to capture the event of adding solid model to a drawing? Or is it advisable to use a bracket function?Thanks in advance.Please email me an answer if any. Do not call please.Feliks. Error Messages / Warnings Reason for Closure Currently not supported Closure Details At present there is no Creo
Per call C11285851 - tech support suggested to fill up a 'Product Idea' The reason for check mode functionality in OTK is the same as in Pro/Toolkit - users can build their own UI. If an app cannot query the current mode it is going to be some crashes.
Already have an account? Login
No account yet? Create an account
Enter your E-mail address. We'll send you an e-mail with instructions to reset your password.