Skip to main content
Jun 19, 2025 10:06 PM UTC
Acknowledged

display the stress amplitude calculated from multiple load sets in a fringe diagram

Related products:Creo Parametric

1. Describe the Problem

I would like a feature to display the stress amplitude calculated from multiple load sets in a fringe diagram. I assume that it is calculated internally during fatigue analysis, so I expect it to be relatively easy to implement. (The case number is C17848775.)


2. Are you using a workaround?
I bought FENFAT and created a program. https://femfat.magna.com/

3. What is the use case for your organization?
It is necessary when evaluating fatigue strength using static analysis.

4. What impact does this problem currently have on your organization?
I have 100 customers who are likely to use it.

2 replies

Community Manager
Jun 20, 2025 9:44 AM UTC
Status changed to: Acknowledged

Thank you @Kitazawa_sgk for your idea. Based on the information you provided, we are acknowledging it as the Community management team. This is not a commitment from the Product team. Other users may comment and vote your idea up.

Jul 11, 2025 3:32 PM UTC

I think I had a similar request a number of years ago.   Being able to see worst case stresses compiled from multiple load cases can improve design evaluation efficiency.

 

https://community.ptc.com/t5/Creo-Parametric-Ideas/Maximum-Stress-Report/idi-p/468173