Recently active
Creo 3 M110 (not M010, my typo in previous post).
So Martin's suggestion is working for you?
Yes. That didn't work either.
Tom,Thanks for the input. But nothing worked for me. I changed the letter settings, as shown below, but the output to the pdf was still all black. Also, I added the pen_table_file to the config.pro, and that didn't help either. I would use Creo 4, but McAfee is still blocking the install, as we discussed in the other post.
I tried it with each and every font setting, and I didn't see any problems. (Creo 3 M010)
Did the developers ever bring back the capability to toggle between the averaged and unaveraged stresses? This is required to check for continuity, and PTC did away with this when they acquired it from RASNA (Mechanica). Christo Katsis admitted that this was an oversight by PTC and was going to bring it back. But it is my understanding that he doesn't work for PTC anymore.
Erleben Sie am Donnerstag, 18. Mai 2017 um 10:30 Uhr die Live-Demonstration von Creo 4.0 und sehen Sie, wie Sie intelligenter konstruieren können.Erfahren Sie mehr in unserem 45-minütigen Webcast über:Verbesserungen bei der ModellierungIntuitivere und flexiblere Interaktionen in Creo DirectVerbesserter Umgang mit FremddatenErweiterungen bei der flexiblen ModellierungLesen Sie mehr auf dem Creo Blog
Based on Case https://support.ptc.com/apps/case_logger_viewer/auth/ssl/case=13638041(Issue 261379)When migrating from one Integrity version to another one, existing (personal) viewsets are not automatically migrated and updated if e.g. the viewset on the server changes.Thus, every user with personal viewsets needs to create his viewsets again, which is very time consuming all in all.Their definitions are stored in the user directory and could be manually copied to the user directory for the new version,but often we encountered problems with this method - furthermore, new client functionality (menus) and optimizations are not carried over (because it's just a copy).We would like to request a solution, which could transfer viewsets, which are derived from the server standard one to the next client version:Like this:* A1 is the standard viewset in the old client version* A2 is the updated standard viewset in the new client* A1' is the personal viewset derived (copied) from A1 in the old c
Based on Case https://support.ptc.com/apps/case_logger_viewer/auth/ssl/case=13595071(Issue 281311)See also https://support.ptc.com/appserver/cs/view/solution.jsp?n=CS259060Change behaviour of Add related item dialog:a) a configurable query is being opened by this dialog (configurable by the end user).b) the query last executed is being openedc) in "Add Related Item" Dialog the Query to be used can be selected from a drop down listd) the query active in the IMS main window is being usede) at least only the issues able to be selected (not closed, canceled, duplicated etc.) should be shown.Perfect would be the possibility to modify the query or to create a new query while the dialog "Items on <server>" is open and being able to use the new query to limit the list of selectable items.
SeeCHGFTPA NAMEFMT(*PATH) CURDIR(*HOMEDIR)Much like doing FTP from command line and then use NAMEFMT 1 to switch from the library/file format on a put to doing a /qsys.lib/mkslib.lib/xyz.savf format.When trying to distribute to a system set up like this failure is the end result.Please do not try to workaround this by usingnamefmt 0in the MKS ftp scripts. Why? Because our target system is also using GoAnywhere and it's setup to keep you in the namefmt 1 situation and if you try the command namefmt 0 it will tell you unpleasant things.
It seems that something happened to the rating of points:
Can someone explain at high level the actions required to upgrade from the older UI to the new 11.x
If so, this site could use a wee bit of updating (look to the right, in a few spots)IBM i® Change Management with PTC Implementer | PTC
Here is a preview of how the agenda is shaping up so far, looks like a full set of meetings all the way through Friday. There is still some opportunity for change. Thursday Hour 1 –Workflow and best practice for showing part annotations in an assembly - goal for this session would be to see if there is customer desire to escalate improvements into Creo 5 (William Cockrell, Mark Nielsen) Current behavior - have to show dims in part before showing in assemblyAdjustments to annotation position can only be made at the part levelSeparable vs. Inseparable Assemblies - Does current annotation behavior meet the needs of both?Hour 2 – Proper Semantic Annotation for Patterns (Ryan Gelotte)We all know the value of “semantic” annotations. But what about patterns? From a visual standpoint, there is value in having an annotation semantically linked to the surfaces of every member of a pattern. This way there is no risk of misinterpreting the design intent. B
It tooks long time, but the problem was solved. Problem: Some drawing symbol is related to view, but icon Unrelate is grayed out or missing in pop-up menu. Source of problem:Symbol is placed on any snap line. This situation is signalyzed by "square with filled dot" in symbol placement point. A) Symbol 3,2 is freeB) Symbol 1,6 is placed on snapline. How to unrelate drawing symbol:1. move a symbol out of snap line2. pick desired symbol3. icon unrelate is functional now AND pop-up menu includes Unrelate too This "problem" was going to make me crazy for a long time. Now l´m happy from this solution and share it with PTC communityBest regardsMilan Bonka
Good day Gents,Monday is the Boston Marathon and I will be out of the office cheering on the crazies doing harm to themselves.Friday I will be returning to my high school to participate in their career fair and I will be speaking about careers in technology & social media.I will be checking into the community from time to time, but if anything big pops up, would you please ping me - - Thank you.I am putting the final touches on a Q2 Community recap deck for you and thinking about a meeting 4/27 or 4/29; your thoughts on those dates?Regarding a Q2 Recap Meeting - do you have questions for me; anything specific you would like addressed?Have a super weekend and as always, thank you for your help.Best,Toby
Where are the Amount Custom fields' labels & data type stored in the database ?ThanksRegardsNate
In conjunction with the release of SPM Version 11.3 the PTC SPM Product Management Team will be hosting a webinar to overview the long list of enhancements in the release. As a member of the Service Parts Management group you are cordially invited to attend. The webinar will take place on Thursday, April 27th at 2:00 p.m. Eastern Time. A separate meeting invitation will follow.We will overview the following features and more:GeneralOnline Help with Google SearchNetwork OptimizationUse Driving Distance and Driving TimeSupport Location/Site Region in ScenarioEnable Bing MapsForecastingReplacement Rate Forecasting and Replacement Rate Detail GUIForecast Review and ApprovalCausal Forecasting ImprovementsFailure Rate/MTBF override workflowHistorical Data VisibilityNew Forecast Review Page with Forecasting MetricsEnhanced Forecast Analysis ViewInventory OptimizationInvestment vs. Product Availability Exchange Curves with MIMEContingency (No Supply) Planning for Product Availabili
Preeti Gupta, ArrowP Inc will help guide the PTC/USER Community on how to maximize its use and get started on developing "killer" apps. Register now for today's presentation (20 Apr 2017) at 11:00 AM EST. Registration details below-https://attendee.gotowebinar.com/register/6905736047825040131
There's a ton of good information on that site... and I'm unable to access it. Is the site down? or is it just me?
When you are using a WTUser as a workflow variable, you might have noticed that Windchill displays all users in the system. I personally find the Setup Participants and Resource Pools a bit much for simple tasks. I want to give a user, say and administrator or manager, a task to delegate future tasks to another user. I create a variable of type WTUser. The user who gets this task will see a drop down list of users, all users in the entire system. Now, if you have a moderate size system of a few hundred users, this will be a very long list. Plus, not all the users will have the necessary rights to complete future workflow tasks. You want to limit this drop down list.This is done via a data utility and a custom JSP task template page. I have create a framework to write your own. In one example, a user might want to limit the list to members of the Product or Library.So, you get a drop down list like this:Sorting and default user selection also po
Does the upper tube have the same axis as the lower tube as shown below?
The component with the warnings is snapped into the assembly ONLY by csys. I called TS, but as usual, I got voicemail. So I’m turning to the Community for some assistance. What I really want to know is how to fix the model where the warnings will no longer appear. Can this be fixed?
If your drawing is selected, and you use the RMB and select delete, this will delete all the geometry, and leave everything else, as shown below. This may be what have done. Try it on a test sample.
Can you provide a sketch? You also have the "pin" constraint.http://support.ptc.com/help/creo/creo_sim/usascii/#page/sim%2Fsimulate%2Fmodstr%2Fconstrnt%2Freference%2FConstr_Pin_Ball_Planar.html%23wwconnect_header
Already have an account? Login
No account yet? Create an account
Enter your E-mail address. We'll send you an e-mail with instructions to reset your password.