Re: Von Mise stress higher than Max Principal Stress?
When PTC switched from Independent Mechanica to Integrated Mode, the developers removed the capability to check for continuity across element edges and implemented averaging techniques. I submitted a Product Idea to bring this functionality back, but it has never amounted to anything. No surprise there.
https://www.ptcusercommunity.com/ideas/2230
There are three components to solution governance: 1) code verification, 2) data verification, and 3) solution verification. Code verification is the responsibility of the developers. Data and solution verifications is the responsibility of the end user.