I agree that it would make things easier. In the meantime you might try placing your volume on a layer and then selecting that layer while creating the measure. I have never tried it before but I am guessing it will work.
In Simulate go into your layer tree, create a new layer and then select the volume to include on that layer. When you go to define your measure by layers, a list of the layers will show up and you can select the one that you just created.
Steven, I will take a look at doing this for an assembly over the weekend. I would have thought that by simply creating the measure at the part level, you could select the "visible at higher assembly level". But it looks like you can't use this option for a measure created by layer. I am thinking you may have to delete the layer in the part model and create a layer in the assembly model for this to work. I will try it and will let you know what I come up with.
Steven, I was not able to get it to work as I had thought it might, but I have another recommendation for you. Create your volume as you have shown in your previous pictures and then run your analysis on you assembly. Once you define the results window, under the display location tab select by volume and then select the volume on you part. Once you display the results this way, you can go to the info drop down and click on model max or model min, and the min and max of the volume only will be displayed. This might be a way to help you get what you need.
Thanks,
Jon