Skip to main content
Jul 4, 2019 1:38 PM UTC
Solved

Wrong inertia (???)

Hi all,

 

It seems that the marked 2-2 inertia values have been replaced in every case. Iyy and Izz.

(File/Prepair/Model Prop/Mass Prop <--> Analysis/Mass Prop)

Is it normal?

Thank you for the answers.

Jul 5, 2019 7:18 PM UTC

Hi,

  • in left dialog box you use default CSYS
  • in right dialog box you use non-default CSYS named CSYS

I think the above two CSYS have y and z axes pointing in different directions.

2 replies

Jul 5, 2019 7:18 PM UTC

Hi,

  • in left dialog box you use default CSYS
  • in right dialog box you use non-default CSYS named CSYS

I think the above two CSYS have y and z axes pointing in different directions.

bopetiAuthor
Jul 29, 2019 12:31 PM UTC

Yes, you are right, thank you