Quantity split clircle BOM balloon the default

We have decided to standardize on the quantity split balloon as our standard callout on engineering assembly drawings.  However, the default balloon when placing is the simple circle balloon.   To switch we need to change the table properties every time. 

 

Anyway to make quantity split balloon the standard when dropping them into a drawing?

BenLoosliAnswer
Nov 20, 2024 4:17 PM UTC

In your .dtl file assigned to your drawing template or set in your drawing template the following:

default_bom_balloon_type quantity_split_circle

 

2 replies

BenLoosliAnswer
Nov 20, 2024 4:17 PM UTC

In your .dtl file assigned to your drawing template or set in your drawing template the following:

default_bom_balloon_type quantity_split_circle

 

Nov 20, 2024 4:23 PM UTC

Awesome,  Thanks Ben