Skip to main content
Aug 1, 2018 5:12 AM UTC
Solved

Model check not running after M050 upgrade.

In our office, we recently updated all the systems to M050 from M040. During M040 versions, all systems were running the model check correctly. After the upgrade, only few systems are working fine and the others are not running the model check in any mode. MCDIR is set correctly in the environmental variables. How we could fix this.

 

Regards

    Aug 6, 2018 12:40 PM UTC

    Hi,

    start commands are .psf files located in Creo4_loadpoint\Creo 4.0\M050\Parametric\bin directory. Default name is parametric.psf. License assigned to .psf file is specified in ENV=CREOPMA_FEATURE_NAME= line.

    5 replies

    Aug 1, 2018 1:42 PM UTC

    M040 or M050 of what version, creo3, creo2, creo4?

    MCDIR has been replaced by another variable recently. Check the documentation, I found this CS article.

    https://www.ptc.com/en/support/article?n=CS57367

    cloniAuthor
    Aug 2, 2018 5:03 AM UTC

    Its Creo 4.0 M050. And when I save my file, it flashes a quick message 'Option ModelCHECK is not available'. In some systems using MCDIR variable, it works perfectly.

    Aug 3, 2018 10:47 AM UTC

    Hi,

    'Option ModelCHECK is not available' message prbably means that your license does not contain ModelCHECK. Please check it.