Skip to main content
Jun 7, 2018 12:13 PM UTC
Question

managing units

Hi,

My prt and asm units are setup on millimeter Newton Second (mmNs).

So pro_mp_mass is in tonnes.

 

 

However, I would like to dispay mass in kilogram on drawing.

Is it possible to manage the unit of pro_mp_mass in a drawing table ?

(Without to write a relation in each part like "my_mass=pro_mp_mass/1000)...

Thanks,

Dominique

6 replies

Jun 7, 2018 12:22 PM UTC

Hi @Dom_CHENTRE

 

 change units in your models to mm kg sec. Change it in your start templates for future using...

mm_kg_sec.jpg

 

It doesn´t matter if you are using Kg or Newtons. Only diference can be in FEM analysis. The output from calculation can be in MPa instead of Pa. No influence for regular modeling.

 

Regards

@mbonka

Jun 7, 2018 12:29 PM UTC

Thanks,

That's I've always did.

But I need to send those files to company that makes FEM and dynamics analysis for me.
They asked me to use mmNs, so I can't use my drawing templates with Pro_mp_mass anymore...

Jun 7, 2018 12:48 PM UTC

Can´t help you Smiley Sad My praxis is following: Using kg for regular modeling and change it to Newtons for FEM.

How many components do you send them? Just a few? They can change units to Newtons for FEM using.

If you don´t wish to use relations than l have no idea how to solve your problem Smiley Sad

Jun 7, 2018 12:51 PM UTC

If you can't change the models' units, and you don't want to write relations in the model, then maybe consider writing relations in the drawing table.  You just need a repeat region - even a single cell repeat region will work.

Jun 7, 2018 2:24 PM UTC

Writing relations in drawing tables seems to be a good solution.

How ever, I' can't do it.

When the cell contains "Pro_mp_mass [.1]", I get the weight

When the cell contains "Pro_mp_mass [.1] / 1000" or something like that, I just get this line as a text.

Where could I found where to find how to do ?

Thanks,

Dominique

Jun 7, 2018 3:14 PM UTC

You need to use "repeat region relations".  Maybe start here:

http://support.ptc.com/cs/cs_27/howto/dwt_relt/dwt_relt.htm