Skip to main content
Nov 30, 2016 2:07 AM UTC
Solved

A bug about reviewing the total load?

When you put a force load on the flat surface, you review total load,and the result is right; But when you put a force on the sphere surface,the result is wrong, do you all encounter this kind of problem? Attached is the images.

1.1.JPG

2.2.JPG

3.3.JPG

4.4.JPG

5.5.JPG

Nov 30, 2016 8:08 PM UTC

This is strange, and not good. I just ran a simple Simulate static analysis (Creo 3 M080) and the output reported -1000N as the resultant system load, just as was defined:

   Load Set: LoadSet1: LOAD_TEST

      Resultant Load on Model:
         in global X direction: -2.008443e-11
         in global Y direction:  2.360514e-11
         in global Z direction: -1.000000e+03

So, at least the analysis of the model is using the correct load value. I always check this reported value in the output file to make sure something did not go wrong. Certainly the internal "Review Total Load" tool needs to be fixed.

Sounds like an SPR needs to be created...right Mark or Jose?

Cheers,

Chris

9 replies

Nov 30, 2016 2:27 PM UTC

Test / creo simulate 2.0 m080: OK

load_creo2_m080.JPG

-------------------------------------------------------------------------------------------------------------------------------------------------------------------

Test / creo simulate 3.0 m110: wrong

load_creo3_m110.JPG

Regards

Paul

y于_01Author
Nov 30, 2016 3:56 PM UTC

Paul,

you are right. I'm using Creo3.0 m110,and Creo 1.0,2.0 have no this problem.

Nov 30, 2016 8:08 PM UTC

This is strange, and not good. I just ran a simple Simulate static analysis (Creo 3 M080) and the output reported -1000N as the resultant system load, just as was defined:

   Load Set: LoadSet1: LOAD_TEST

      Resultant Load on Model:
         in global X direction: -2.008443e-11
         in global Y direction:  2.360514e-11
         in global Z direction: -1.000000e+03

So, at least the analysis of the model is using the correct load value. I always check this reported value in the output file to make sure something did not go wrong. Certainly the internal "Review Total Load" tool needs to be fixed.

Sounds like an SPR needs to be created...right Mark or Jose?

Cheers,

Chris

y于_01Author
Dec 1, 2016 1:07 AM UTC

Christopher,you are right ,the internal "Review Total Load" tool needs to be fixed. I tested this several months ago.When I create a force measure of that direction,the result in the rpt file is right.That's why I still use this FEM even though this bug exists. Pasted below are some images I've made:

1.1.JPG

2.2.JPG

3.3.JPG

Dec 8, 2016 4:20 PM UTC

Please file a bug report ASAP.

Review total load tool is fundamental and we use it all the time ... currently on a client project using 3.0/M110

atb

Dec 21, 2016 10:58 AM UTC

test / creo 4.0:

load_results_creo4.jpg

y于_01Author
Dec 22, 2016 1:31 PM UTC

There is still no fix about this bug in Creo4.0 Simulate, what a pity!